Dynamic tracking of ischemia in the surface electrocardiogram

被引:11
作者
Shusterman, Vladimir [1 ]
Goldberg, Anna
Schindler, Daniel M.
Fleischmann, Kirsten E.
Lux, Robert L.
Drew, Barbara J.
机构
[1] Univ Pittsburgh, Cardiovasc Inst, Pittsburgh, PA 15213 USA
[2] PinMed Inc, Pittsburgh, PA USA
[3] UCSF, Francisco, CA USA
[4] Univ Utah, Cardiovasc Res & Training Inst, Salt Lake City, UT USA
关键词
ischemia; electrocardiography; monitoring;
D O I
10.1016/j.jelectrocard.2007.06.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Accurate detection of the earliest signs of ischemia on the surface electrocardiogram (ECG) is essential for timely diagnosis and management of potentially life-threatening ischemic events. Yet, accuracy of ischemia analysis in ECG monitors remains suboptimal because of a number of confounding factors, including changes in body position and other artifacts. Hence, the goals of this study were (1) to examine the duration and time course of ischemic events and (2) to compare ECG changes caused by "true" ischemic events with those caused by changes in body position. Continuous, 12-lead Holler ECCs obtained from patients who presented to the emergency department with chest pain and enrolled in the Ischemia Monitoring and Mapping in the Emergency Department in Appropriate Triage and Evaluation of Acute Ischemic Myocardium study were analyzed. Holier recordings were initiated within the first 40 minutes after patients' arrival to the emergency department. Here we present preliminary results. Methods: Twelve patients (age, 59 16 years; 5 women, 2 with a final diagnosis of non-ST-segment elevation myocardial infarction, 4 with unstable angina, and 6 with other cardiovascular diseases), in whom ischemic ST deviations were identified on Holier data, underwent 4 consecutive, 2-minute recordings in the following body positions: (1) supine, (2) on the left side, (3) on the right side, and (4) sitting (or standing) upright. After baseline correction, beat-to-beat changes in QRS and ST-T segments were examined in all 8 channels and the root-mean-square curve by using an adaptive algorithm that computes the slope, amplitude, duration, area, and the Karhunen-Loeve-derived representation of the corresponding segment. To prevent possible biases toward patients with more frequent ischemic events, a single index event was chosen for analysis in each patient. There were 3 ST-elevation events and 9 ST-depression events; these events reached the maximum ST deviation 11 +/- 8 hours (mean +/- SD) after the beginning of the recording. Results and Conclusions: In most patients with transient myocardial ischemia, the microvolt-level, subthreshold deviation of the ST segment developed gradually, over 15 to 20 minutes, until it reached the maximum, superthreshold level. Despite the different ischemia localizations, the root-mean-square curve allowed accurate detection of significant changes in the ST segment in the studied group (Friedman analysis of variance for repeated measurements over a 1-hour interval). Changes in body position could be identified by tracking dynamics of the QRS pattern/axis. Adaptive algorithms for tracking of the ST dynamics with simultaneous tracking of the patterns of QRS complexes to discriminate the true and "false"-positive events are presented and discussed. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:S179 / S186
页数:8
相关论文
共 14 条
[1]   Efficacy of 2 strategies to detect body position ST-segment changes during continuous 12-lead electrocardiographic monitoring [J].
Adams, MG ;
Drew, BJ .
JOURNAL OF ELECTROCARDIOLOGY, 2002, 35 :193-200
[2]   Detection of body position changes using the surface electrocardiogram [J].
Åström, M ;
García, J ;
Laguna, P ;
Pahlm, O ;
Sörnmo, L .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (02) :164-171
[3]   ACC/AHA Guidelines for Ambulatory Electrocardiography - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines - (Committee to revise the guidelines for ambulatory electrocardiography) - Developed in collaboration with the North American society for pacing and electrophysiology [J].
Crawford, MH ;
Bernstein, SJ ;
Deedwania, PC ;
DiMarco, JP ;
Ferrick, KJ ;
Garson, A ;
Green, LA ;
Greene, HL ;
Silka, MJ ;
Stone, PH ;
Tracy, CM ;
Gibbons, RJ ;
Alpert, JS ;
Eagle, KA ;
Gardner, TJ ;
Garson, A ;
Gregoratos, G ;
Russell, RO ;
Ryan, TJ ;
Smith, SC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (03) :912-945
[4]   Clinical consequences of ST-segment changes caused by body position mimicking transient myocardial ischemia: Hazards of ST-segment monitoring? [J].
Drew, BJ ;
Adams, MG .
JOURNAL OF ELECTROCARDIOLOGY, 2001, 34 (03) :261-264
[5]   ECG-based detection of body position changes in ischemia monitoring [J].
García, J ;
Åström, M ;
Mendive, J ;
Laguna, P ;
Sörnmo, L .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (06) :677-685
[6]   Automatic detection of ST-T complex changes on the ECG using filtered RMS difference series:: Application to ambulatory ischemia monitoring [J].
García, J ;
Sörnmo, L ;
Olmos, S ;
Laguna, P .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (09) :1195-1201
[7]   Detection of transient ST segment episodes during ambulatory ECG monitoring [J].
Jager, F ;
Moody, GB ;
Mark, RG .
COMPUTERS AND BIOMEDICAL RESEARCH, 1998, 31 (05) :305-322
[8]  
Norgaard BL, 1999, J ELECTROCARDIOL, V32, P149
[9]  
Shusterman V., 1994, Systems Analysis and Modelling Simulation, V14, P15
[10]   Tracking repolarization dynamics in real-life data [J].
Shusterman, V ;
Goldberg, A .
JOURNAL OF ELECTROCARDIOLOGY, 2004, 37 :180-186