Relation of heart rate and blood pressure turbulence following premature ventricular complexes to baroreflex sensitivity in chronic congestive heart failure

被引:138
作者
Davies, LC
Francis, DP
Ponikowski, P
Piepoli, MF
Coats, AJS
机构
[1] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, London, England
[2] Mil Hosp, Dept Cardiol, Wroclaw, Poland
基金
英国惠康基金;
关键词
D O I
10.1016/S0002-9149(00)01493-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reduced heart rate variability (HRV) and attenuated baroreflex sensitivity (BS) after myocardial infarction and in patients with chronic congestive heart failure (CHF) are associated with poor prognosis. Recent studies have shown that a large proportion of the prognostic power from HRV measurements is localized in heart rare turbulence immediately after ventricular premature complexes. The mechanism of heart rate turbulence remains unknown. In the present study, we explore its relation to BS. In 45 patients with CHF and greater than or equal to3 ectopic beats in a 30-minute period, measurements of RR interval and continuous, noninvasive blood pressure (BP) were studied at rest. In response to an ectopic beat, average heart rate turbulence was 9.4 ms/beat (SD 6.1), Mean BP turbulence was 0.72 mm Hg/beat (SD 0.56). Using the ratio of heart rate and BP turbulence slopes to estimate BS showed good agreement (r = 0.67, p < 0.0001) with the cu-index method (BS,). This relation was attributable to a marked correlation between heart rate turbulence and BS, (r = 0.70, p <0.0001); there was no correlation between BP turbulence and the BSalpha (r = 0.1, p = NS). Twenty-nine percent of patients had postectopic pulsus alternans, with a mean decoy time of 1.4 beats (SD 0.5). The presence of pulsus alternans was associated with a significantly lower heart rate turbulence slope [6.3 [SEM 1.0] vs 10.7 [SEM 1.2] ms/beat, p = 0.03). Thus, heart rate turbulence is an effective measure of the baroreflex, correlating strongly with a standard measure. This is because it is the heart rate, rather than the BP, response to an ectopic beat that conveys the information relevant to BS measurement. (C) 2001 by Excerpta Medica, Inc.
引用
收藏
页码:737 / 742
页数:6
相关论文
共 25 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[3]   Reproducibility of methods for assessing baroreflex sensitivity in normal controls and in patients with chronic heart failure [J].
Davies, LC ;
Francis, DP ;
Jurák, P ;
Kára, T ;
Piepoli, M ;
Coats, AJS .
CLINICAL SCIENCE, 1999, 97 (04) :515-522
[4]  
FARRELL TG, 1992, BRIT HEART J, V67, P129
[5]   Fifteen years experience with finger arterial pressure monitoring: assessment of the technology [J].
Imholz, BPM ;
Wieling, W ;
van Montfrans, GA ;
Wesseling, KH .
CARDIOVASCULAR RESEARCH, 1998, 38 (03) :605-616
[6]  
KRUGER C, 1997, AM J PHYSIOL-HEART C, V273, pH2240
[7]  
La Rovere MT, 1998, LANCET, V351, P478
[8]  
Lewis T, 1911, Q J MED, V4, P141
[9]   ALTERNATING CONTRACTILITY IN PULSUS ALTERNANS STUDIED IN THE ISOLATED CANINE HEART [J].
MCGAUGHEY, MD ;
MAUGHAN, WL ;
SUNAGAWA, K ;
SAGAWA, K .
CIRCULATION, 1985, 71 (02) :357-362
[10]   END-SYSTOLIC PRESSURE-DIAMETER RELATIONSHIPS DURING PULSUS ALTERNANS IN INTACT PIG HEARTS [J].
MILLER, WP ;
LIEDTKE, AJ ;
NELLIS, SH .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 250 (04) :H606-H611