Reproducibility of methods for assessing baroreflex sensitivity in normal controls and in patients with chronic heart failure

被引:94
作者
Davies, LC
Francis, DP
Jurák, P
Kára, T
Piepoli, M
Coats, AJS
机构
[1] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, London, England
[2] Acad Sci Czech Republ, Inst Sci Instruments, CS-61264 Brno, Czech Republic
[3] St Anna Fac Hosp, Dept Internal Med Cardiol 1, Brno, Czech Republic
关键词
baroreflex sensitivity; chronic heart failure; reproducibility;
D O I
10.1042/CS19990135
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Baroreflex sensitivity (BRS) conveys useful prognostic information in patients with heart disease, yet methods for its quantification suffer from poor reproducibility and test failure in some patients with heart failure. We set out to compare the short-term reproducibility and success rate of four different methods of assessing BRS in normal subjects and patients with chronic heart failure (CHF). A total of 31 patients with CHF and 18 normal controls underwent BRS testing using four techniques: (1) bolus phenylephrine (BRSPhe), (2) alpha-index in both low- and high- frequency bands (BRSalpha LF and BRSalpha HF respectively), (3) the sequence method (BRSSeq), and (4) a new 0.1 Hz controlled-breathing, time-domain analysis method (BRSCbr). Each subject underwent two test episodes with each method on the same day. The average values for BRS in patients and controls respectively were: BRSPhe, 4.4 (+/-4.4) ms/mmHg and 19.8 (+/-11.5) ms/mmHg; BRSalpha LF, 5.6 (+/- 4. 1) ms/mmHg and 15.4 (+/- 5.0) ms/mmHg; BRSalpha HF, 7.1 (+/- 7.0) ms/mmHg and 25.1 (+/-8.3) ms/mmHg; BRSSeq, 7.7 (+/-6.3) ms/mmHg and 22.5 (+/-8.4) ms/mmHg; BRSCbr, 6.6 (+/-5.9) ms/mmHg and 22.8 (+/-10.8) ms/mmHg. The coefficients of variation (S.D. of the difference in repeated values divided by mean) in patients and controls respectively were: BRSPhe, 85.6% and 52.2%; BRSalpha LF, 65.9% and 33.7%; BRSalpha HF, 99.7% and 52.1%; BRSSeq, 30.7% and 40.4%; BRSCbr, 30.7% and 19.6%. The numbers of test failures in patients were: BRSPhen, 15; BRS alpha LF, 7; BRSalpha HF, 5; BRSSeq, 14; BRSCbr, 1. Of the four techniques assessed for measuring BRS, the controlled breathing time-domain method yielded the best reproducibility and lowest failure rate in controls and in patients with CHF.
引用
收藏
页码:515 / 522
页数:8
相关论文
共 28 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] IMPORTANT INFLUENCE OF RESPIRATION ON HUMAN R-R INTERVAL POWER SPECTRA IS LARGELY IGNORED
    BROWN, TE
    BEIGHTOL, LA
    KOH, J
    ECKBERG, DL
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (05) : 2310 - 2317
  • [3] Depressed baroreflex sensitivity in patients with obstructive sleep apnea
    Carlson, JT
    Hedner, JA
    Sellgren, J
    Elam, M
    Gunnar, B
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (05) : 1490 - 1496
  • [4] Controlled breathing protocols probe human autonomic cardiovascular rhythms
    Cooke, WH
    Cox, JF
    Diedrich, AM
    Taylor, JA
    Beightol, LA
    Ames, JE
    Hoag, JB
    Seidel, H
    Eckberg, DL
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (02): : H709 - H718
  • [5] DAWSON SL, 1997, J CLIN AUTONOMIC RES, V7, P1
  • [6] FARRELL TG, 1992, BRIT HEART J, V67, P129
  • [7] How high can a correlation coefficient be? Effects of limited reproducibility of common cardiological measures
    Francis, DP
    Coats, AJS
    Gibson, DG
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 69 (02) : 185 - 189
  • [8] A DIRECT EXCITATORY ACTION OF CATECHOLAMINES ON RAT AORTIC BARORECEPTORS INVITRO
    GOLDMAN, WF
    SAUM, WR
    [J]. CIRCULATION RESEARCH, 1984, 55 (01) : 18 - 30
  • [9] Mid- and long-term reproducibility of noninvasive measurements of spontaneous arterial baroreflex sensitivity in healthy volunteers
    Herpin, D
    Ragot, S
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1997, 10 (07) : 790 - 797
  • [10] Iellamo F, 1996, J HYPERTENS, V14, P1099