Glioma grading by using histogram analysis of blood volume heterogeneity from MR-derived cerebral blood volume maps

被引:133
作者
Emblem, Kyrre E. [1 ,4 ]
Nedregaard, Baard [2 ]
Nome, Terje [2 ]
Due-Tonnessen, Paulina [2 ]
Hald, John K. [2 ]
Scheie, David [3 ]
Borota, Olivera Casar [3 ]
Cvancarova, Milada
Bjornerud, Atle [1 ]
机构
[1] Rikshosp Radiumhosp, Med Ctr, Dept Med Phys, N-0027 Oslo, Norway
[2] Rikshosp Radiumhosp, Med Ctr, Dept Neuroradiol, N-0027 Oslo, Norway
[3] Rikshosp Radiumhosp, Med Ctr, Dept Pathol, N-0027 Oslo, Norway
[4] Rikshosp Radiumhosp, Med Ctr, Intervent Ctr, N-0027 Oslo, Norway
关键词
D O I
10.1148/radiol.2473070571
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively compare the diagnostic accuracy of an alternative method used to grade gliomas that is based on histogram analysis of normalized cerebral blood volume (CBV) values from the entire tumor volume (obtained with the histogram method) with that of the hot-spot method, with histologic analysis as the reference standard. Materials and Methods: The medical ethics committee approved this study, and all patients provided informed consent. Fifty-three patients (24 female, 29 male; mean age, 48 years; age range, 14-76 years) with histologically confirmed gliomas were examined with dynamic contrast material-enhanced 1.5-T magnetic resonance (MR) imaging. CBV maps were created and normalized to unaffected white matter (normalized CBV maps). Four neuroradiologists independently measured the distribution of whole-tumor normalized CBVs and analyzed this distribution by classifying the values into area-normalized bins. Glioma grading was performed by assessing the normalized peak height of the histogram distributions. Logistic regression analysis and interobserver agreement were used to compare the proposed method with a hot-spot method in which only the maximum normalized CBV was used. Results: For the histogram method, diagnostic accuracy was independent of the observer. Interobserver agreement was almost perfect for the histogram method (kappa = 0.923) and moderate for the hot-spot method (kappa = 0.559). For all observers, sensitivity was higher with the histogram method (90%) than with the hot-spot method (55%-76%). Conclusion: Glioma grading based on histogram analysis of normalized CBV heterogeneity is an alternative to the established hot-spot method, as it offers increased diagnostic accuracy and interobserver agreement. (C) RSNA, 2008.
引用
收藏
页码:808 / 817
页数:10
相关论文
共 29 条
[1]   Dynamic susceptibility contrast MRI of gliomas [J].
Aronen, HJ ;
Perkiö, J .
NEUROIMAGING CLINICS OF NORTH AMERICA, 2002, 12 (04) :501-+
[2]   CEREBRAL BLOOD-VOLUME MAPS OF GLIOMAS - COMPARISON WITH TUMOR GRADE AND HISTOLOGIC-FINDINGS [J].
ARONEN, HJ ;
GAZIT, IE ;
LOUIS, DN ;
BUCHBINDER, BR ;
PARDO, FS ;
WEISSKOFF, RM ;
HARSH, GR ;
COSGROVE, GR ;
HALPERN, EF ;
HOCHBERG, FH ;
ROSEN, BR .
RADIOLOGY, 1994, 191 (01) :41-51
[3]  
Bjornerud A, 2003, P HUM BRAIN MAPPING, P19
[4]  
Boxerman JL, 2006, AM J NEURORADIOL, V27, P859
[5]   Survival rates and patterns of care for patients diagnosed with supratentorial low-grade gliomas - Data from the SEER program, 1973-2001 [J].
Claus, EB ;
Black, PM .
CANCER, 2006, 106 (06) :1358-1363
[6]   Dynamic magnetic resonance perfusion imaging of brain tumors [J].
Covarrubias, DJ ;
Rosen, BR ;
Lev, MH .
ONCOLOGIST, 2004, 9 (05) :528-537
[7]  
Donahue KM, 2000, MAGNET RESON MED, V43, P845, DOI 10.1002/1522-2594(200006)43:6<845::AID-MRM10>3.0.CO
[8]  
2-J
[9]   CEREBRAL BLOOD-FLOW - ASSESSMENT WITH DYNAMIC CONTRAST-ENHANCED T2-STAR-WEIGHTED MR IMAGING AT 1.5-T [J].
EDELMAN, RR ;
MATTLE, HP ;
ATKINSON, DJ ;
HILL, T ;
FINN, JP ;
MAYMAN, C ;
RONTHAL, M ;
HOOGEWOUD, HM ;
KLEEFIELD, J .
RADIOLOGY, 1990, 176 (01) :211-220
[10]   THE EFFICACY OF DIAGNOSTIC-IMAGING [J].
FRYBACK, DG ;
THORNBURY, JR .
MEDICAL DECISION MAKING, 1991, 11 (02) :88-94