Ultrasound-to-computer-tomography registration for image-guided laparoscopic liver surgery

被引:35
作者
Bao, P
Warmath, J
Galloway, R
Herline, A
机构
[1] Vanderbilt Univ, Med Ctr, Dept Surg, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37232 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2005年 / 19卷 / 03期
关键词
image-guided surgery; ultrasound; computer tomography; registration; laparoscopic surgery; liver;
D O I
10.1007/s00464-004-8902-1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The application of image-guided surgery (IGS) to laparoscopic liver resection and ablation is currently limited, but it would assist in intraoperative decision making regarding oncologic margins, ablation probe placement, and ablation tracking. Methods: Eight spherical surface targets on a liver phantom were imaged with an optically tracked laparoscopic ultrasound (US) probe. Ten US images of each target were registered to computer tomography (CT) images of the phantoms and then mapped to the CT scans. Accuracy of the registration was assessed by comparing the distance between the predicted target location and the position obtained directly from CT. Results: The average localization error was 5.3 mm. The errors resulted primarily from inaccurate US probe tracking but were otherwise insensitive to the variability that arises from manually identifying targets in US and CT images. Conclusions: The results obtained for US-to-CT registration in a phantom model suggest that further investigations into its clinical use are warranted and that other IGS technologies could be applied to laparoscopic liver surgery as well.
引用
收藏
页码:424 / 429
页数:6
相关论文
共 19 条
[1]   Laparoscopy extends the indications for liver resection in patients with cirrhosis [J].
Abdel-Atty, MY ;
Farges, O ;
Jagot, P ;
Belghiti, J .
BRITISH JOURNAL OF SURGERY, 1999, 86 (11) :1397-1400
[2]   Tracked ultrasound for laparoscopic surgery [J].
Bao, P ;
Warmath, J ;
Poulose, B ;
Galloway, R ;
Herline, A .
MEDICAL IMAGING 2004: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2004, 5367 :237-246
[3]  
Batchelor P., 2001, Medical image registration, P39
[4]  
BEASLEY RA, 2000, P SOC PHOTO-OPT INS, V1, P282
[5]   Laparoscopic liver resections:: A feasibility study in 30 patients [J].
Cherqui, D ;
Husson, E ;
Hammoud, R ;
Malassagne, B ;
Stéphan, F ;
Bensaid, S ;
Rotman, N ;
Fagniez, PL .
ANNALS OF SURGERY, 2000, 232 (06) :753-761
[6]  
Chung MH, 2001, SURG ENDOSC-ULTRAS, V15, P1020
[7]   Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[8]   INTERACTIVE IMAGE-GUIDED NEUROSURGERY [J].
GALLOWAY, RL ;
MACIUNAS, RJ ;
EDWARDS, CA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (12) :1226-1231
[9]   Laparoscopic liver resection for malignant liver tumors - Preliminary results of a multicenter European study [J].
Gigot, JF ;
Glineur, D ;
Azagra, JS ;
Goergen, M ;
Ceuterick, M ;
Morino, M ;
Etienne, J ;
Marescaux, J ;
Mutter, D ;
van Krunckelsven, L ;
Descottes, B ;
Valleix, D ;
Lachachi, F ;
Bertrand, C ;
Mansvelt, B ;
Hubens, G ;
Saey, JP ;
Schockmel, R .
ANNALS OF SURGERY, 2002, 236 (01) :90-97
[10]  
Herline A, 2000, SURG ENDOSC-ULTRAS, V14, P675