A Gaussian mixture model for definition of lung tumor volumes in positron emission tomography

被引:82
作者
Aristophanous, Michalis [1 ]
Penney, Bill C.
Martel, Mary K.
Pelizzari, Charles A.
机构
[1] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
positron emission tomography; mixture model; tumor volume segmentation;
D O I
10.1118/1.2791035
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The increased interest in F-18-fluorodeoxyglucose (FDG) positron emission tomography (PET) in radiation treatment planning in the past five years necessitated the independent and accurate segmentation of gross tumor volume (GTV) from FDG-PET scans. In some studies the radiation oncologist contours the GTV based on a computed tomography scan, while incorporating pertinent data from the PET images. Alternatively, a simple threshold, typically 40% of the maximum intensity, has been employed to differentiate tumor from normal tissue, while other researchers have developed algorithms to aid the PET based GTV definition. None of these methods, however, results in reliable PET tumor segmentation that can be used for more sophisticated treatment plans. For this reason, we developed a Gaussian mixture model (GMM) based segmentation technique on selected PET tumor regions from non-small cell lung cancer patients. The purpose of this study was to investigate the feasibility of using a GMM-based tumor volume definition in a robust, reliable and reproducible way. A GMM relies on the idea that any distribution, in our case a distribution of image intensities, can be expressed as a mixture of Gaussian densities representing different classes. According to our implementation, each class belongs to one of three regions in the image; the background (B), the uncertain (U) and the target (T), and from these regions we can obtain the tumor volume. User interaction in the implementation is required, but is limited to the initialization of the model parameters and the selection of an "analysis region" to which the modeling is restricted. The segmentation was developed on three and tested on another four clinical cases to ensure robustness against differences observed in the clinic. It also compared favorably with thresholding at 40% of the maximum intensity and a threshold determination function based on tumor to background image intensities proposed in a recent paper. The parts of the method that are user dependent were evaluated and resulted in initial estimates of the method's precision, which is in the order of +/- 10% of the average tumor volume estimate. With this work we have established the applicability of the GMM-based segmentation on clinical studies and we have made an initial assessment of the method's precision with respect to tumor volume segmentation. (C) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:4223 / 4235
页数:13
相关论文
共 29 条
[11]  
Erdi YE, 1997, CANCER, V80, P2505, DOI 10.1002/(SICI)1097-0142(19971215)80:12+<2505::AID-CNCR24>3.0.CO
[12]  
2-F
[13]   Radiotherapy treatment planning for patients with non-small cell lung cancer using positron emission tomography (PET) [J].
Erdi, YE ;
Rosenzweig, K ;
Erdi, AK ;
Macapinlac, HA ;
Hu, YC ;
Braban, LE ;
Humm, JL ;
Squire, OD ;
Chui, CS ;
Larson, SM ;
Yorke, ED .
RADIOTHERAPY AND ONCOLOGY, 2002, 62 (01) :51-60
[14]   Current status of PET/CT for tumour volume definition in radiotherapy treatment planning for non-small cell lung cancer (NSCLC) [J].
Greco, Carlo ;
Rosenzweig, Kenneth ;
Cascini, Giuseppe Lucio ;
Tamburrini, Oscar .
LUNG CANCER, 2007, 57 (02) :125-134
[15]   The contribution of 18F-fluoro-2-deoxy-glucose positron emission tomographic imaging to radiotherapy planning in lung cancer [J].
Kiffer, JD ;
Berlangieri, SU ;
Scott, AM ;
Quong, G ;
Feigen, M ;
Schumer, W ;
Clarke, CP ;
Knight, SR ;
Daniel, FJ .
LUNG CANCER, 1998, 19 (03) :167-177
[16]   PARAMETER-ESTIMATION OF FINITE MIXTURES USING THE EM ALGORITHM AND INFORMATION CRITERIA WITH APPLICATION TO MEDICAL IMAGE-PROCESSING [J].
LIANG, Z ;
JASZCZAK, RJ ;
COLEMAN, RE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :1126-1133
[17]   PARAMETER-ESTIMATION AND TISSUE SEGMENTATION FROM MULTISPECTRAL MR-IMAGES [J].
LIANG, ZR ;
MACFALL, JR ;
HARRINGTON, DP .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (03) :441-449
[18]   Towards multidimensional radiotherapy (MD-CRT): Biological imaging and biological conformality [J].
Ling, CC ;
Humm, J ;
Larson, S ;
Amols, H ;
Fuks, Z ;
Leibel, S ;
Koutcher, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (03) :551-560
[19]  
McLachlam GJ., 2000, FINITE MIXTURE MODEL
[20]   18F-deoxyglucose positron emission tomography (FDG-PET) for the planning of radiotherapy in lung cancer:: High impact in patients with atelectasis [J].
Nestle, U ;
Walter, K ;
Schmidt, S ;
Licht, N ;
Nieder, C ;
Motaref, B ;
Hellwig, D ;
Niewald, M ;
Ukena, D ;
Kirsch, CM ;
Sybrecht, GW ;
Schnabel, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (03) :593-597