A website for blood pressure measuring devices: dableducational.com

被引:26
作者
O'Brien, E [1 ]
机构
[1] Beaumont Hosp, ADAPT Ctr, Dept Clin Pharmacol, Dublin, Ireland
[2] Beaumont Hosp, Blood Pressure Unit, Dublin, Ireland
[3] Royal Coll Surgeons Ireland, Dept Clin Pharmacol, Dublin 2, Ireland
关键词
website; blood pressure measurement; sphygmomanometers; validation; manufacturers;
D O I
10.1097/00126097-200308000-00010
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Consumers are faced with an ever-increasing array of blood pressure measuring devices, whether for use in clinical areas or for use by individuals anxious to measure their own blood pressure. Validation protocols that allow for independent evaluation of blood pressure measuring devices are available, and some of the devices on the market have been evaluated according to these protocols. The results of such evaluations have been published periodically in medical journals. However, such surveys are not readily available to the public and to health care authorities with responsibility for purchasing blood pressure measuring equipment for use in clinical medicine, and because of the necessarily lengthy publication process they are no longer up-to-date at the time of publication. Moreover, the results of published validation studies are often flawed because of protocol violations and the conclusions may not be valid. These considerations have been the stimulus for the establishment of an independent non-profit website, which will provide quarterly updates on the accuracy and performance of blood pressure measuring devices on the market as well as an expert assessment of the validation procedures on which recommendations are based. The ethos of the website is primarily educational and it is hoped that it will serve as a forum for the provision of much-needed information that will ultimately improve the management of hypertension. The website is due to be launched shortly and this paper outlines the general principles that have governed its establishment and the facilities that it will provide. (C) 2003 Lippincott Williams Wilkins.
引用
收藏
页码:177 / 180
页数:4
相关论文
共 7 条
[1]  
*AM NAT STAND, ANSI AAMI SP
[2]  
[Anonymous], BMJ
[3]   European Society of hypertension recommendations for conventional, ambulatory and home blood pressure measurement [J].
O'Brien, E ;
Asmar, R ;
Beilin, L ;
Imai, Y ;
Mallion, JM ;
Mancia, G ;
Mengden, T ;
Myers, M ;
Padfield, P ;
Palatini, P ;
Parati, G ;
Pickering, T ;
Redon, J ;
Staessen, J ;
Stergiou, G ;
Verdecchia, P .
JOURNAL OF HYPERTENSION, 2003, 21 (05) :821-848
[4]   Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults [J].
O'Brien, E ;
Pickering, T ;
Asmar, R ;
Myers, M ;
Parati, G ;
Staessen, J ;
Mengden, T ;
Imai, Y ;
Waeber, B ;
Palatini, P ;
Atkins, N ;
Gerin, W .
BLOOD PRESSURE MONITORING, 2002, 7 (01) :3-17
[5]   State of the market in 2001 for blood pressure measuring devices [J].
O'Brien, E .
BLOOD PRESSURE MONITORING, 2001, 6 (04) :171-176
[6]  
O'Brien E., 1993, J HYPERTENSION S2, V11, P43, DOI DOI 10.1097/00004872-199306000-00013
[7]   STATE OF THE MARKET - A REVIEW OF AMBULATORY BLOOD-PRESSURE MONITORING DEVICES [J].
OBRIEN, E ;
ATKINS, N ;
STAESSEN, J .
HYPERTENSION, 1995, 26 (05) :835-842