Elimination of interference information by a new hybrid algorithm for quantitative calibration of near infrared spectra

被引:28
作者
Chen, D [1 ]
Wang, F [1 ]
Shao, XG [1 ]
Su, QD [1 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China
关键词
D O I
10.1039/b305023h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new hybrid algorithm is proposed to eliminate the interference information for multivariate calibration of near-infrared (NIR) spectra that includes noise, background and systemic spectral variation irrelevant to concentration. The method consists of two parts: approximate derivative based on continuous wavelet transform (CWT) and orthogonal signal correction (OSC). After the approximate derivative calculated by CWT, OSC was performed. It was successfully applied to real complex NIR spectral data to eliminate the interference information. Correction for the interference of NIR spectra resulted in a substantial improvement in the predicted precision, and a more concise calibration model was obtained. The proposed procedure also compared favourably with several pretreatment methods, and the new method appears to provide a high-performance pretreatment tool for multivariate calibration of NIR spectra. In addition, the strategy proposed here can be applied to various other spectral data for quantitative purposes as well.
引用
收藏
页码:1200 / 1203
页数:4
相关论文
共 27 条
  • [1] Direct orthogonalization
    Andersson, CA
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 47 (01) : 51 - 63
  • [2] The continuous wavelet transform, an analysis tool for NMR spectroscopy
    Barache, D
    Antoine, JP
    Dereppe, JM
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1997, 128 (01) : 1 - 11
  • [3] STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA
    BARNES, RJ
    DHANOA, MS
    LISTER, SJ
    [J]. APPLIED SPECTROSCOPY, 1989, 43 (05) : 772 - 777
  • [4] Simultaneous determination of drugs in concentration ratios above 40:1 by application of multivariate calibration to absorbance and derivative spectrophotometric signals
    Bautista, RD
    Jimenez, AI
    Jimenez, F
    Arias, JJ
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (04): : 449 - 456
  • [5] Effect of orthogonal signal correction on the determination of compounds with very similar near infrared spectra
    Bertran, E
    Iturriaga, H
    Maspoch, S
    Montoliu, I
    [J]. ANALYTICA CHIMICA ACTA, 2001, 431 (02) : 303 - 311
  • [6] Derivative preprocessing and optimal corrections for baseline drift in multivariate calibration
    Brown, CD
    Vega-Montoto, L
    Wentzell, PD
    [J]. APPLIED SPECTROSCOPY, 2000, 54 (07) : 1055 - 1068
  • [7] HIGH-RESOLUTION DERIVATIVE SPECTRA IN REMOTE-SENSING
    DEMETRIADESSHAH, TH
    STEVEN, MD
    CLARK, JA
    [J]. REMOTE SENSING OF ENVIRONMENT, 1990, 33 (01) : 55 - 64
  • [8] MULTICOMPONENT DETERMINATION OF THE PESTICIDE NAPTALAM AND ITS METABOLITES IN RIVER WATER, BY APPLYING PARTIAL LEAST-SQUARES CALIBRATION TO THE DERIVATIVE SPECTROPHOTOMETRIC SIGNALS
    DIAZ, TG
    VALENZUELA, MIA
    SALINAS, F
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (12): : 692 - 701
  • [9] Orthogonal signal correction, wavelet analysis, and multivariate calibration of complicated process fluorescence data
    Eriksson, L
    Trygg, J
    Johansson, E
    Bro, R
    Wold, S
    [J]. ANALYTICA CHIMICA ACTA, 2000, 420 (02) : 181 - 195
  • [10] On orthogonal signal correction
    Fearn, T
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 50 (01) : 47 - 52