Dual-Echo Dixon Imaging with Flexible Choice of Echo Times

被引:298
作者
Eggers, Holger [1 ]
Brendel, Bernhard [1 ]
Duijndam, Adri [2 ]
Herigault, Gwenael [2 ]
机构
[1] Philips Res, Hamburg, Germany
[2] Philips Healthcare, Best, Netherlands
关键词
water-fat separation; fat suppression; Dixon methods; multiecho acquisitions; abdominal imaging; eddy currents; WATER-FAT DECOMPOSITION; SEPARATION; ACQUISITION; ALGORITHM; H-1-NMR; PROTON;
D O I
10.1002/mrm.22578
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
In this work, a new two-point method for water-fat imaging is described and explored. It generalizes existing two-point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two-point method promises to provide more freedom in the selection of protocol parameters and to reach higher scan efficiency. Its performance was studied theoretically and was evaluated experimentally in abdominal imaging with a multi-gradient-echo sequence. While depending on the choice of echo times, it is generally found to be favorable compared to existing two-point methods. Notably, water images with higher spatial resolution and better signal-to-noise ratio were attained with it in single breathholds at 3.0 T and 1.5 T, respectively. The use of more accurate spectral models of fat is shown to substantially reduce observed variations in the extent of fat suppression. The acquisition of in-and opposed-phase images is demonstrated to be replaceable by a synthesis from water and fat images. The new two-point method is finally also applied to autocalibrate a multidimensional eddy current correction and to enhance the fat suppression achieved with three-point methods in this way, especially toward the edges of larger field of views. Magn Reson Med 65:96-107, 2011. (c) 2010 Wiley-Liss, Inc.
引用
收藏
页码:96 / 107
页数:12
相关论文
共 23 条
[1]
MR IMAGING - CLINICAL USE OF THE INVERSION RECOVERY SEQUENCE [J].
BYDDER, GM ;
YOUNG, IR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :659-675
[2]
SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[3]
EGGERS H, 2009, P ISMRM, P2705
[4]
EGGERS H, 2008, P 16 ANN M ISMRM TOR, P1364
[5]
MULTIPOINT DIXON TECHNIQUE FOR WATER AND FAT PROTON AND SUSCEPTIBILITY IMAGING [J].
GLOVER, GH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05) :521-530
[6]
3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION [J].
GLOVER, GH ;
SCHNEIDER, E .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :371-383
[7]
H-1-NMR CHEMICAL-SHIFT SELECTIVE (CHESS) IMAGING [J].
HAASE, A ;
FRAHM, J ;
HANICKE, W ;
MATTHAEI, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (04) :341-344
[8]
Algebraic Decomposition of Fat and Water in MRI [J].
Jacob, Mathews ;
Sutton, Bradley P. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (02) :173-184
[9]
[10]
KOKEN P, 2007, P 15 ANN M ISMRM BER, P1623