Development and validation of a simple, sensitive, second antibody format enzyme immunoassay (EIA) for LH determination in mithun (Bos frontalis) plasma

被引:12
作者
Mondal, M [1 ]
Dhali, A
Prakash, B
Rajkhowa, C
Prakash, BS
机构
[1] Natl Res Ctr Mithun ICAR, Nagaland 797106, India
[2] Natl Dairy Res Inst, Div Dairy Cattle Physiol, Karnal 132001, Haryana, India
关键词
mithun endocrinology; LH; plasma; EIA; semi-wild; validation;
D O I
10.1081/IAS-200052003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The objective of this study was to develop and validate a simple and highly sensitive enzyme immunoassay (EIA) for LH determination in mithun plasma on microtitreplates using the biotin-streptavidin amplification system and the second antibody coating technique. Biotin was coupled to LH and used to bridge between streptavidin-peroxidase and immobilized antiserum in competitive assay. The EIA was carried out directly in 20 mu L mithun plasma. The LH standards ranging from 6.25 pg/well/20 mu L to 400 pg/well/20 mu L were prepared in hormone free plasma collected from a mithun on day 3 post calving. The sensitivity of EIA procedure was 6.25 pg/well LH, which corresponds to 0.31 ng/mL plasma; the 50 percent relative binding sensitivity was seen at 100 pg/well/20 mu L. Plasma volumes for the EIA viz. 10 and 20 mu L did not influence the shape of standard curve even though a slight drop in the OD450 was seen with higher plasma volumes. A parallelism test was carried out to compare the endogenous mithun plasma LH with bovine LH standards. It showed good parallelism with the bovine standard curve. For the biological validation of the assay, 3 mithuns were used. These were administered 10 mu g i.v., with a synthetic analogue of GnRH (Buserelin-Acetate, Intervet, India) and blood samples were collected at 15 min intervals using indwelling jugular catheter beginning 1 h prior to GnRH injection till 8 h post injection. In all animals, sharp increases in LH concentrations were recorded post GnRH administration, which confirms the biological validation of the EIA. In conclusion, the EIA developed for LH determination in mithun blood plasma is sufficiently reliable, economical, and sensitive enough to estimate LH in all physiological variations in mithun.
引用
收藏
页码:157 / 167
页数:11
相关论文
共 16 条
[11]  
MEYER HHD, 1986, STUDIES ANIMAL PRODU, P255
[12]   DEVELOPMENT OF A SENSITIVE ENZYME-IMMUNOASSAY FOR LH DETERMINATION IN BOVINE PLASMA USING THE STREPTAVIDIN-BIOTIN TECHNIQUE [J].
MUTAYOBA, BM ;
MEYER, HHD ;
SCHAMS, D ;
SCHALLENBERGER, E .
ACTA ENDOCRINOLOGICA, 1990, 122 (02) :227-232
[13]   RADIOIMMUNOASSAY FOR BOVINE AND OVINE LUTEINIZING HORMONE [J].
NISWENDER, GD ;
REICHERT, LE ;
MIDGLEY, AR ;
NALBANDOV, AV .
ENDOCRINOLOGY, 1969, 84 (05) :1166-+
[14]   Development and validation of a simple sensitive enzyme immunoassay (EIA) for GH determination in buffalo plasma [J].
Prakash, BS ;
Mondal, M ;
Anandlaxmi, N .
JOURNAL OF IMMUNOASSAY & IMMUNOCHEMISTRY, 2003, 24 (04) :409-420
[15]   Development of a sensitive enzymeimmunoassay (EIA) for FSH determination in bovine plasma [J].
Prakash, BS ;
Wallenhorst, S ;
Metten, M ;
Holtz, W ;
Wuttke, W .
ANIMAL REPRODUCTION SCIENCE, 1999, 55 (3-4) :183-192
[16]   SEASONAL-VARIATIONS IN OESTRADIOL-17-BETA AND LUTEINIZING-HORMONE IN THE BLOOD OF BUFFALO COWS (BUBALUS-BUBALIS) [J].
RAO, LV ;
PANDEY, RS .
JOURNAL OF ENDOCRINOLOGY, 1983, 98 (02) :251-255