摘要
A simple and sensitive method has been developed for the determination of tributyltin (TBT) in aqueous samples and environmental samples. Automated in-tube solid-phase microextraction (SPME) and high-performance liquid chromatography (HPLC) were coupled to a quadrupole mass spectrometer (MS) using electrospray (ES) as an ionization source. To achieve optimum performance, the conditions for both in-tube SPME and ES-MS detection were optimized for the analysis of TBT. A commercially available capillary, Supel-Q PLOT, showed the best extraction efficiency for TBT and, therefore, it was selected for in-tube SPME. The in-tube SPME-HPLC-ES-MS method provided a linear relationship between the analyte concentration and signal intensity in the range of 0.5-200 ng mL(-1) TBT, with a detection limit of 0.05 ng mL(-1). The method performance was evaluated by determining the content of TBT in a sediment reference material (PACS-2).
引用
收藏
页码:159 / 165
页数:7
相关论文
共 37 条
[11]  
KWM SIU, 1988, RAPID COMMUN MASS SP, V2, P201
[12]  
Lawson G, 1996, APPL ORGANOMET CHEM, V10, P125
[13]   DETERMINATION OF TRACE AMOUNTS OF BUTYL-TIN COMPOUNDS IN AQUEOUS SYSTEMS BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY [J].
MEINEMA, HA ;
BURGERWIERSMA, T ;
VERSLUISDEHAAN, G ;
GEVERS, EC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1978, 12 (03) :288-293
[14]  
Mester Z, 1999, RAPID COMMUN MASS SP, V13, P1999, DOI 10.1002/(SICI)1097-0231(19991030)13:20<1999::AID-RCM744>3.3.CO
[15]  
2-3
[16]   Speciation of trimethyllead and triethyllead by in-tube solid phase microextraction high-performance liquid chromatography electrospray ionization mass spectrometry [J].
Mester, Z ;
Lord, H ;
Pawliszyn, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (06) :595-600
[17]   Determination of methylmercury by solid-phase microextraction inductively coupled plasma mass spectrometry: a new sample introduction method for volatile metal species [J].
Mester, ZN ;
Lam, J ;
Sturgeon, R ;
Pawliszyn, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (07) :837-842
[18]   Sensitive, simultaneous determination of organomercury, -lead, and -tin compounds with headspace solid phase microextraction capillary gas chromatography combined with inductively coupled plasma mass spectrometry [J].
Moens, L ;
DeSmaele, T ;
Dams, R ;
VandenBroeck, P ;
Sandra, P .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1604-1611
[19]   TRIBUTYLTIN DETECTION AT TRACE LEVELS IN WATER AND SEDIMENTS USING GC WITH FLAME-PHOTOMETRIC DETECTION AND GC-MS [J].
MUELLER, MD .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 317 (01) :32-36
[20]  
Pawliszyn J., 1999, APPL SOLID PHASE MIC