Preparation of ultrafine silica- and PEG-coated magnetite particles

被引:164
作者
Butterworth, MD [1 ]
Illum, L [1 ]
Davis, SS [1 ]
机构
[1] Univ Nottingham, Inst Pharmaceut Sci, Nottingham NG7 2RD, England
关键词
magnetite particles; PEG coating; trimethoxysilane-PEG; diagnostic imaging;
D O I
10.1016/S0927-7757(00)00633-6
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The effect of the molecular weight, reaction temperature and polymer concentration were investigated. The PEG coverage could be controlled by the selection of the polymer; the molecular coverage increased with decrease in polymer molecular weight. A method for synthesising PEG-coated magnetite particles for use in diagnostic imaging is described. Magnetite particles in aqueous conditions were reacted with Si(OR)(2)R'R" (trimethosysilane-PEG, R = Me; R' = Ome; R" = PEG). These PEG-coated magnetite particles showed greatly enhanced colloid stability properties with respect to the uncoated particles. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:93 / 102
页数:10
相关论文
共 28 条
[1]   INITIAL CLINICAL-EXPERIENCE WITH DEXTRAN-COATED SUPERPARAMAGNETIC IRON-OXIDE FOR DETECTION OF LYMPH-NODE METASTASES IN PATIENTS WITH HEAD AND NECK-CANCER [J].
ANZAI, Y ;
BLACKWELL, KE ;
HIRSCHOWITZ, SL ;
ROGERS, JW ;
SATO, Y ;
YUH, WTC ;
RUNGE, VM ;
MORRIS, MR ;
MCLACHLAN, SJ ;
LUFKIN, RB .
RADIOLOGY, 1994, 192 (03) :709-715
[2]  
BOOKER NA, 1994, PROCESS SAF ENVIRON, V72, P109
[3]   POLY(ETHYLENE GLYCOL) GRAFTED TO QUARTZ - ANALYSIS IN TERMS OF A SITE-DISSOCIATION MODEL OF ELECTROOSMOTIC FLUID-FLOW [J].
BURNS, NL ;
VANALSTINE, JM ;
HARRIS, JM .
LANGMUIR, 1995, 11 (07) :2768-2776
[4]  
DAVIS S, IN PRESS
[5]  
DIXON DR, 1985, RES REV
[6]   POLYSTYRENE-POLY(ETHYLENE GLYCOL) (PS-PEG2000) PARTICLES AS MODEL SYSTEMS FOR SITE-SPECIFIC DRUG-DELIVERY .2. THE EFFECT OF PEG SURFACE-DENSITY ON THE IN-VITRO CELL-INTERACTION AND IN-VIVO BIODISTRIBUTION [J].
DUNN, SE ;
BRINDLEY, A ;
DAVIS, SS ;
DAVIES, MC ;
ILLUM, L .
PHARMACEUTICAL RESEARCH, 1994, 11 (07) :1016-1022
[7]   ESTIMATION OF THE POLY(ETHYLENE GLYCOL) CHAIN-LENGTH OF L-POLYLACTIDE-POLYETHYLENE GLYCOL IN AQUEOUS DISPERSIONS USING VISCOELASTIC MEASUREMENTS [J].
HAGAN, SA ;
DAVIS, SS ;
ILLUM, L ;
DAVIES, MC ;
GARNETT, MC ;
TAYLOR, DC ;
IRVING, MP ;
TADROS, TF .
LANGMUIR, 1995, 11 (05) :1482-1485
[8]   Preparation of biodegradable, surface engineered PLGA nanospheres with enhanced lymphatic drainage and lymph node uptake [J].
Hawley, AE ;
Illum, L ;
Davis, SS .
PHARMACEUTICAL RESEARCH, 1997, 14 (05) :657-661
[9]   TARGETING OF COLLOIDS TO LYMPH-NODES - INFLUENCE OF LYMPHATIC PHYSIOLOGY AND COLLOIDAL CHARACTERISTICS [J].
HAWLEY, AE ;
DAVIS, SS ;
ILLUM, L .
ADVANCED DRUG DELIVERY REVIEWS, 1995, 17 (01) :129-148
[10]   Lymph node localisation of biodegradable nanospheres surface modified with poloxamer and poloxamine block co-polymers [J].
Hawley, AE ;
Illum, L ;
Davis, SS .
FEBS LETTERS, 1997, 400 (03) :319-323