Effects of the cell geometry and operating parameters on the performance of an external contactless conductivity detector for microchip electrophoresis

被引:69
作者
Kubán, P [1 ]
Hauser, PC [1 ]
机构
[1] Univ Basel, Dept Chem, CH-4004 Basel, Switzerland
关键词
D O I
10.1039/b418845d
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantitative data on the effect of the electrode geometry on the signal strength and the signal-to-noise ratio is given. The measurements are affected by the unavoidable presence of stray capacitance. Best results are achieved for short and narrow electrodes arranged in an antiparallel configuration and separated by a minimal gap, which determines the dimensions of the actual detection volume. Limits of detection between 150 and 250 mu g l(-1) and separation efficiencies from 13 000 to 17 000 theoretical plates were achieved for six inorganic cations (NH4+, K+, Ca2+, Na+, Mg2+ and Li+) with electrodes of 1 mm width and a detection gap of 0.5 mm ( separation channel length: 7.5 cm) when operating the detector at 20 V-pp and 500 kHz. The analyses of all major inorganic cations in tap and rain water samples were demonstrated for the first time in microchip electrophoresis with contactless conductivity detection.
引用
收藏
页码:407 / 415
页数:9
相关论文
共 60 条
[1]   Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements [J].
Abad-Villar, EM ;
Tanyanyiwa, J ;
Fernández-Abedul, MT ;
Costa-García, A ;
Hauser, PC .
ANALYTICAL CHEMISTRY, 2004, 76 (05) :1282-1288
[2]  
Baldwin RP, 2000, ELECTROPHORESIS, V21, P4017, DOI 10.1002/1522-2683(200012)21:18<4017::AID-ELPS4017>3.3.CO
[3]  
2-X
[4]  
Baltussen E, 2002, ELECTROPHORESIS, V23, P2888, DOI 10.1002/1522-2683(200209)23:17<2888::AID-ELPS2888>3.0.CO
[5]  
2-4
[6]  
Berthold A, 2002, ELECTROPHORESIS, V23, P3511, DOI 10.1002/1522-2683(200210)23:20<3511::AID-ELPS3511>3.0.CO
[7]  
2-C
[8]   Isotachophoresis and isotachophoresis -: zone electrophoresis separations of inorganic anions present in water samples on a planar chip with column-coupling separation channels and conductivity detection [J].
Bodor, R ;
Madajová, V ;
Kaniansky, D ;
Masár, M ;
Jöhnck, M ;
Stanislawski, B .
JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) :155-165
[9]   Dual photometric-contactless conductometric detector for capillary electrophoresis [J].
Chvojka, T ;
Jelínek, I ;
Opekar, F ;
Stulík, K .
ANALYTICA CHIMICA ACTA, 2001, 433 (01) :13-21
[10]  
da Silva JAF, 1998, ANAL CHEM, V70, P4339