Validation of spiral computed tomography for dental implants

被引:28
作者
Cavalcanti, MGP [1 ]
Yang, J [1 ]
Ruprecht, A [1 ]
Vannier, MV [1 ]
机构
[1] Univ Sao Paulo, Fac Odontol, Dept Radiol, BR-05508 Sao Paulo, Brazil
关键词
tomography; X-ray computed; dental implantation; mandible; image processing; computer-assisted;
D O I
10.1038/sj.dmfr.4600386
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To investigate the accuracy of 2DCT orthoradial reformatted images from spiral computed tomography (CT) for pre-surgical planning of dental implants in proximity to the mental foramen. Methods: Eight cadaver heads were imaged by spiral CT (S/Xpress, Toshiba - America, Tustin, CA) with I mm thick axial slices by I mm/sec of table feed. The image data set was transferred to a networked computer workstation. Using computer graphics the data was analysed with 2D orthoradial reformatting using the ToothPix(TM) (Cemax, Fremont, CA, USA) protocol. Linear measurements were made by two oral radiologists independently from the superior border of the mental foramen to the crest of the alveolar process and from the inferior border of the mental foramen to the mandibular inferior border. The soft tissues were removed and physical measurements made using a 3 Space(TM) (Polhemus, Colchester, VT) electromagnetic digitizer with a personal computer running Windows(R) 95. Results: The differences between the measurements on orthoradial 2DCT images and the physical measurements were not statistically significant (P > 0.05). Conclusions: Two-dimensional spiral CT imaging allows highly accurate measurements for dental implant placement in proximity to the mental foramen. Computer graphics software, using reformatted reconstruction, is suitable for implant planning.
引用
收藏
页码:329 / 333
页数:5
相关论文
共 18 条
[1]  
ABRAHAMS JJ, 1993, AM J NEURORADIOL, V14, P979
[2]   CLINICAL USEFULNESS OF 2-DIMENSIONAL REFORMATTED AND 3-DIMENSIONALLY RENDERED COMPUTERIZED TOMOGRAPHIC-IMAGES - LITERATURE-REVIEW AND A SURVEY OF SURGEONS OPINIONS [J].
ALDER, ME ;
DEAHL, ST ;
MATTESON, SR .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1995, 53 (04) :375-386
[3]  
BESSIMO C, 1995, DENTOMAXILLOFAC RAD, V24, P264
[4]   Three dimensional spiral CT for craniofacial surgical planning and evaluation [J].
Cavalcanti, MGP ;
Vannier, MW .
SURGICAL-ASSIST SYSTEMS, PROCEEDINGS OF, 1998, 3262 :26-34
[5]  
DELBALSO A, 1993, RADIOLOGY, V22, P92
[6]   ROLE OF DIAGNOSTIC-IMAGING IN EVALUATION OF THE DENTAL IMPLANT PATIENT [J].
DELBALSO, AM ;
GREINER, FG ;
LICATA, M .
RADIOGRAPHICS, 1994, 14 (04) :699-719
[7]   VALIDATION-STUDY OF SKULL 3-DIMENSIONAL COMPUTERIZED-TOMOGRAPHY MEASUREMENTS [J].
HILDEBOLT, CF ;
VANNIER, MW ;
KNAPP, RH .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1990, 82 (03) :283-294
[8]   3-DIMENSIONAL MEASUREMENT ACCURACY OF SKULL SURFACE LANDMARKS [J].
HILDEBOLT, CF ;
VANNIER, MW .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1988, 76 (04) :497-503
[9]  
JAMES R A, 1991, Journal of Oral Implantology, V17, P10
[10]   COMPARISON OF 2-DIMENSIONAL ORTHORADIALLY REFORMATTED COMPUTED-TOMOGRAPHY AND PANORAMIC RADIOGRAPHY FOR DENTAL IMPLANT TREATMENT PLANNING [J].
LAM, EWN ;
RUPRECHT, A ;
YANG, J .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 74 (01) :42-46