The implications of water quality in hemodialysis

被引:31
作者
Hoenich, NA
Levin, R
机构
[1] Newcastle Univ, Sch Clin Med Sci, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
[2] Renal Res Inst, New York, NY USA
关键词
D O I
10.1046/j.1525-139X.2003.16106.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Water used in dialysis requires additional treatment to minimize patient exposure to potential contaminants that may be present in drinking water. Although standards for the chemical purity of water are in existence and have eliminated many of the problems seen in renal units in the 1970s, some problems remain, and the importance of newer contaminants arising from changes in water treatment at the municipal level are being recognized. Despite this, recent surveys have indicated considerable shortcomings in compliance with chemical standards. The water quality used in the preparation of dialysis fluid also requires minimal bacterial content. Staff working in renal units are frequently unaware of the level of microbiologic contamination in their dialysis fluid arising from the presence of biofilm in the dialysis machines and the water distribution network. Bacterial fragments generated by such biofilms are able to cross the dialysis membrane and stimulate an inflammatory response in the patient. Such inflammation has been implicated in the mortality and morbidity associated with dialysis. The desire to improve treatment outcomes has led to the application of more stringent standards for the microbiologic purity of dialysis fluid and to the introduction of ultraclean dialysis fluid into clinical practice.
引用
收藏
页码:492 / 497
页数:6
相关论文
共 57 条
[1]   DIALYSIS ENCEPHALOPATHY SYNDROME - POSSIBLE ALUMINUM INTOXICATION [J].
ALFREY, AC ;
LEGENDRE, GR ;
KAEHNY, WD .
NEW ENGLAND JOURNAL OF MEDICINE, 1976, 294 (04) :184-188
[2]   AN OUTBREAK OF FATAL FLUORIDE INTOXICATION IN A LONG-TERM HEMODIALYSIS UNIT [J].
ARNOW, PM ;
BLAND, LA ;
GARCIAHOUCHINS, S ;
FRIDKIN, S ;
FELLNER, SK .
ANNALS OF INTERNAL MEDICINE, 1994, 121 (05) :339-344
[3]  
Arvanitidou M, 1999, J NEPHROL, V12, P32
[4]  
AZEVEDO SM, 2002, TOXICOLOGY, P181
[5]   Human intoxication by microcystins during renal dialysis treatment in Caruaru-Brazil [J].
Azevedo, SMFO ;
Carmichael, WW ;
Jochimsen, EM ;
Rinehart, KL ;
Lau, S ;
Shaw, GR ;
Eaglesham, GK .
TOXICOLOGY, 2002, 181 :441-446
[6]   USING ULTRAPURE WATER IN HEMODIALYSIS DELAYS CARPAL-TUNNEL SYNDROME [J].
BAZ, M ;
DURAND, C ;
RAGON, A ;
JABER, K ;
ANDRIEU, D ;
MERZOUK, T ;
PURGUS, R ;
OLMER, M ;
REYNIER, JP ;
BERLAND, Y .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (11) :681-685
[7]   Acute aluminum encephalopathy in a dialysis center caused by a cement mortar water distribution pipe [J].
Berend, K ;
van der Voet, G ;
Boer, WH .
KIDNEY INTERNATIONAL, 2001, 59 (02) :746-753
[8]  
Botella J, 1977, Proc Eur Dial Transplant Assoc, V14, P192
[9]  
Bouchier I, 1998, CRYPTOSPORIDIUM WATE
[10]   Outbreak of hemolytic reactions associated with chlorine and chloramine residuals in hemodialysis water [J].
Calderaro, RVV ;
Heller, L .
REVISTA DE SAUDE PUBLICA, 2001, 35 (05) :481-486