Prediction of the disinfection and oxidation efficiency of full-scale ozone reactors

被引:14
作者
Gallard, H
von Gunten, U [1 ]
Kaiser, HP
机构
[1] EAWAG, Swiss Fed Inst Environm Sci & Technol, CH-8600 Dubendorf, Switzerland
[2] Wasserversorgung Zurich, CH-8023 Zurich, Switzerland
来源
JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA | 2003年 / 52卷 / 04期
关键词
disinfection; modelling of ozone contactors; oxidation kinetics; ozonation; micropollutants;
D O I
10.2166/aqua.2003.0026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The efficiency of a two-step ozonation with regard to disinfection and oxidation of micropollutants; was assessed for a river-water treatment plant (Limmat River, Zurich, Switzerland). The assessment was based on laboratory experiments to estimate transient ozone and OH radical concentrations coupled with hydraulic modelling of the ozone reactors. The laboratory experiments were performed for various temperatures, ozone dosages and pretreatments to mimic the full-scale treatment. The hydraulics were determined by a conservative tracer test. The kinetic data for disinfection and oxidation were taken from the literature. The inactivation of microorganisms (Cryptosporidium parvum oocysts, Bacillus subtilis spores, Giardia lamblia cysts and polio virus) was more critical at low temperature (5degreesC) than at high temperature (20degreesC). For Cryptosporidium parvum oocysts it was calculated to be less than 1 log for the two ozonation steps, and an overall ozone dose of 1.5 mg/l (5degreesC). For the same microorganism it was >3.5-log inactivation at 20degreesC. For other microorganisms, the calculated inactivation was greater than or equal to2 log (5degreesC) with B. subtilis spores being the most resistant. The oxidation of micropollutants was much less affected by variations in the temperature. The fraction of oxidation increased in the following order: between 15 and 25% of tetrachloroethene, 15 and 25% of methyl tertiary butyl ether, 30 and 40% of atrazine, 80 and 90% of p-xylene and between 97 and 100% of trim ethyl benzene were oxidized. For the oxidation of methyl tertiary butyl ether, the formation of degradation products was modelled in the pre-ozonation step. For all investigated treatment conditions the overall bromate formation was less than or equal to2.5 mug/l.
引用
收藏
页码:277 / 290
页数:14
相关论文
共 21 条
[1]   MTBE oxidation by conventional ozonation and the combination ozone/hydrogen peroxide: Efficiency of the processes and bromate formation [J].
Acero, JL ;
Haderlein, SB ;
Schmidt, TC ;
Suter, MJF ;
Von Gunten, U .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (21) :4252-4259
[2]   Degradation kinetics of atrazine and its degradation products with ozone and OH radicals: A predictive tool for drinking water treatment [J].
Acero, JL ;
Stemmler, K ;
Von Gunten, U .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (04) :591-597
[3]  
[Anonymous], FED REG
[4]   DETERMINATION OF OZONE IN WATER BY THE INDIGO METHOD [J].
BADER, H ;
HOIGNE, J .
WATER RESEARCH, 1981, 15 (04) :449-456
[5]   CRITICAL-REVIEW OF RATE CONSTANTS FOR REACTIONS OF HYDRATED ELECTRONS, HYDROGEN-ATOMS AND HYDROXYL RADICALS (.OH/.O-) IN AQUEOUS-SOLUTION [J].
BUXTON, GV ;
GREENSTOCK, CL ;
HELMAN, WP ;
ROSS, AB .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1988, 17 (02) :513-886
[6]   An investigation of the laws of disinfection [J].
Chick, H .
JOURNAL OF HYGIENE, 1908, 8 (01) :92-158
[7]   Inactivation of Bacillus subtilis spores and formation of bromate during ozonation [J].
Driedger, A ;
Staub, E ;
Pinkernell, U ;
Mariñas, B ;
Köster, W ;
Von Gunten, U .
WATER RESEARCH, 2001, 35 (12) :2950-2960
[8]  
DRIEDGER A, 2000, WATER RES, V14, P3591
[9]   Hydroxyl radical/ozone ratios during ozonation processes. II. The effect of temperature, pH, alkalinity, and DOM properties [J].
Elovitz, MS ;
von Gunten, U ;
Kaiser, HP .
OZONE-SCIENCE & ENGINEERING, 2000, 22 (02) :123-150
[10]   Hydroxyl radical ozone ratios during ozonation processes.: I-The Rct concept [J].
Elovitz, MS ;
von Gunten, U .
OZONE-SCIENCE & ENGINEERING, 1999, 21 (03) :239-260