Three-dimensional printing of anatomically accurate, patient specific intracranial aneurysm models

被引:79
作者
Anderson, Jeff R. [1 ]
Thompson, Walker L. [1 ]
Alkattan, Abdulaziz K. [1 ]
Diaz, Orlando [2 ,3 ]
Klucznik, Richard [2 ,3 ]
Zhang, Yi J. [2 ,3 ]
Britz, Gavin W. [2 ,3 ]
Grossman, Robert G. [3 ]
Karmonik, Christof [1 ]
机构
[1] Houston Methodist Res Inst, MRI Core, Houston, TX USA
[2] Houston Methodist Hosp, Cerebrovasc Ctr, Houston, TX USA
[3] Houston Methodist Hosp, Dept Neurosurg, Houston, TX USA
关键词
Aneurysm; MRI; COMPUTATIONAL FLUID-DYNAMICS; 4D FLOW MRI; CEREBRAL ANEURYSMS; IN-VITRO; HEMODYNAMICS; 3D; COILS;
D O I
10.1136/neurintsurg-2015-011686
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Objective To develop and validate a method for creating realistic, patient specific replicas of cerebral aneurysms by means of fused deposition modeling. Methods The luminal boundaries of 10 cerebral aneurysms, together with adjacent proximal and distal sections of the parent artery, were segmented based on DSA images, and corresponding virtual three-dimensional (3D) surface reconstructions were created. From these, polylactic acid and MakerBot Flexible Filament replicas of each aneurysm were created by means of fused deposition modeling. The accuracy of the replicas was assessed by quantifying statistical significance in the variations of their inner dimensions relative to 3D DSA images. Feasibility for using these replicas as flow phantoms in combination with phase contrast MRI was demonstrated. Results 3D printed aneurysm models were created for all 10 subjects. Good agreement was seen between the models and the source anatomy. Aneurysm diameter measurements of the printed models and source images correlated well (r=0.999; p<0.001), with no statistically significant group difference (p=0.4) or observed bias. The SDs of the measurements were 0.5mm and 0.2mm for source images and 3D models, respectively. 3D printed models could be imaged with flow via MRI. Conclusions The 3D printed aneurysm models presented were accurate and were able to be produced inhouse. These models can be used for previously cited applications, but their anatomical accuracy also enables their use as MRI flow phantoms for comparison with ongoing studies of computational fluid dynamics. Proof of principle imaging experiments confirm MRI flow phantom utility.
引用
收藏
页码:517 / 520
页数:5
相关论文
共 32 条
[1]  
Anderson JR, 2014, IEEE ENG MED BIO, P6699, DOI 10.1109/EMBC.2014.6945165
[2]   Intracranial 4D Flow MRI: Toward Individualized Assessment of Arteriovenous Malformation Hemodynamics and Treatment-Induced Changes [J].
Ansari, S. A. ;
Schnell, S. ;
Carroll, T. ;
Vakil, P. ;
Hurley, M. C. ;
Wu, C. ;
Carr, J. ;
Bendok, B. R. ;
Batjer, H. ;
Markl, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (10) :1922-1928
[3]  
Cebral J.R., 2014, Journal of neurointerventional surgery
[4]   Morphologic and Hemodynamic Risk Factors in Ruptured Aneurysms Imaged before and after Rupture [J].
Chien, A. ;
Sayre, J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (11) :2130-2135
[5]   Neurovascular Modeling: Small-Batch Manufacturing of Silicone Vascular Replicas [J].
Chueh, J. Y. ;
Wakhloo, A. K. ;
Gounis, M. J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (06) :1159-1164
[6]  
Costalat V, 2006, AM J NEURORADIOL, V27, P177
[7]   Cerebrovascular biomodelling: A technical note [J].
D'Urso, PS ;
Thompson, RG ;
Atkinson, RL ;
Weidmann, MJ ;
Redmond, MJ ;
Hall, BI ;
Jeavons, SJ ;
Benson, MD ;
Earwaker, WJS .
SURGICAL NEUROLOGY, 1999, 52 (05) :490-500
[8]   Rapid prototyping of three-dimensional biomodels as an adjuvant in the surgical planning for intracranial aneurysms [J].
Erbano, Bruna Olandoski ;
Opolski, Ana Cristina ;
Olandoski, Marcia ;
Foggiatto, Jose Aguiomar ;
Kubrusly, Luiz Fernando ;
Dietz, Ulrich Andreas ;
Zini, Cassio ;
Makita Arantes Marinho, Melissa Mitsue ;
Leal, Andre Giacomelli ;
Ramina, Ricardo .
ACTA CIRURGICA BRASILEIRA, 2013, 28 (11) :756-761
[9]   PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models [J].
Ford, Matthew D. ;
Nikolov, Hristo N. ;
Milner, Jaques S. ;
Lownie, Stephen P. ;
DeMont, Edwin M. ;
Kalata, Wojciech ;
Loth, Francis ;
Holdsworth, David W. ;
Steinman, David A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (02)
[10]   Identification of the Inflow Zone of Unruptured Cerebral Aneurysms: Comparison of 4D Flow MRI and 3D TOF MRA Data [J].
Futami, K. ;
Sano, H. ;
Misaki, K. ;
Nakada, M. ;
Ueda, F. ;
Hamada, J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (07) :1363-1370