Imaging MALDI mass spectrometry using an oscillating capillary nebulizer matrix coating system and its application to analysis of lipids in brain from a mouse model of Tay-Sachs/Sandhoff disease

被引:119
作者
Chen, Yanfeng [1 ]
Allegood, Jeremy [1 ]
Liu, Ying [2 ]
Wang, Elaine [2 ]
Cachon-Gonzalez, Begona [3 ]
Cox, Timothy M. [3 ]
Merrill, Alfred H., Jr. [1 ,2 ]
Sullards, M. Cameron [1 ,2 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biochem, Parker H Petit Inst Bioengn & Biosci, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Biol, Parker H Petit Inst Bioengn & Biosci, Atlanta, GA 30332 USA
[3] Univ Cambridge, Addenbrookes Hosp, Dept Med, Cambridge CB2QQ, England
关键词
D O I
10.1021/ac702350g
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
The quality of tissue imaging by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) depends on the effectiveness of the matrix deposition, especially for lipids that may dissolve in the solvent used for the matrix application. This article describes the use of an oscillating capillary nebulizer (OCN) to spray small droplets of matrix aerosol onto the sample surface for improved matrix homogeneity, reduced crystal size, and controlled solvent effects. This system was then applied to the analysis of histological slices of brains from mice with homozygous disruption of the hexb gene (hexb(-/-)), a model of Tay-Sachs and Sandhoff disease, versus the functionally normal heterozygote (hexb(+/-)) by imaging MALDI-MS. This allowed profiling and localization of many different lipid species, and of particular interest, ganglioside GM2, asialo-GM2 (GA2), and sulfatides (ST). The presence of these compounds was confirmed by analysis of brain extracts using electrospray ionization in conjunction with tandem mass spectrometry (MS/MS). The major fatty acid of the ceramide backbone of both GM2 and GA2 was identified as stearic acid (18:0) versus nervonic acid (24: 1) for ST by both tissue-imaging MS and ESI-MS/MS. GM2 and GA2 were highly elevated in hexb(-/-) and were both localized in the granular cell region of the cerebellum. ST, however, was localized mainly in myelinated fiber (white matter) region of the cerebellum as well as in the brain stem with a relatively uniform distribution and had similar relative signal intensity for both hexb(+/-) and hexb(-/-) brain. It was also observed that there were distinct localizations for numerous other lipid subclasses; hence, imaging MALDI-MS could be used for "lipidomic" studies. These results illustrate the usefulness of tissue-imaging MALDI-MS with matrix deposition by OCN for histologic comparison of lipids in tissues such as brains from this mouse model of Tay-Sachs and Sandhoff disease.
引用
收藏
页码:2780 / 2788
页数:9
相关论文
共 42 条
[1]
Automated acoustic matrix deposition for MALDI sample preparation [J].
Aerni, HR ;
Cornett, DS ;
Caprioli, RM .
ANALYTICAL CHEMISTRY, 2006, 78 (03) :827-834
[2]
Direct molecular Imaging of Lymnaea stagnalis nervous tissue at subcellular spatial resolution by mass spectrometry [J].
Altelaar, AFM ;
van Minnen, J ;
Jiménez, CR ;
Heeren, RMA ;
Piersma, SR .
ANALYTICAL CHEMISTRY, 2005, 77 (03) :735-741
[3]
Axelsson J, 1997, RAPID COMMUN MASS SP, V11, P209, DOI 10.1002/(SICI)1097-0231(19970131)11:2<209::AID-RCM734>3.0.CO
[4]
2-E
[5]
Automated MALDI matrix deposition method with inkjet printing for imaging mass spectrometry [J].
Baluya, Dodge L. ;
Garrett, Timothy J. ;
Yost, Richard A. .
ANALYTICAL CHEMISTRY, 2007, 79 (17) :6862-6867
[6]
Interface for direct and continuous sample-matrix deposition onto a MALDI probe for polymer analysis by thermal field flow fractionation and off-line MALDI-MS [J].
Basile, F ;
Kassalainen, GE ;
Williams, SKR .
ANALYTICAL CHEMISTRY, 2005, 77 (09) :3008-3012
[7]
BENJAMINS JA, 2006, BASIC NEUROCHEMISTRY
[8]
Effective gene therapy in an authentic model of Tay-Sachs-related diseases [J].
Cachon-Gonzalez, M. Begona ;
Wang, Susan Z. ;
Lynch, Andrew ;
Ziegler, Robin ;
Cheng, Seng H. ;
Cox, Timothy M. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (27) :10373-10378
[9]
Trends in sample preparation for classical and second generation proteomics [J].
Canas, Benito ;
Pineiro, Carmen ;
Calvo, Enrique ;
Lopez-Ferrer, Daniel ;
Manuel Gallardo, Jose .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1153 (1-2) :235-258
[10]
Molecular imaging of biological samples: Localization of peptides and proteins using MALDI-TOF MS [J].
Caprioli, RM ;
Farmer, TB ;
Gile, J .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4751-4760