Switching Function Model-Based Fast-Diagnostic Method of Open-Switch Faults in Inverters Without Sensors

被引:216
作者
An, Qun-Tao [1 ]
Sun, Li-Zhi [1 ]
Zhao, Ke [1 ]
Sun, Li [1 ]
机构
[1] Harbin Inst Technol, Dept Elect Engn, Harbin 150001, Heilongjiang, Peoples R China
关键词
Fault diagnosis; inverter; open-circuit fault; switching function model; without sensors; 3-PHASE INDUCTION-MOTOR; PWM INVERTER; TOLERANT; DRIVE; RECONFIGURATION; STRATEGIES; MACHINE; SYSTEM; ALGORITHM; TOPOLOGY;
D O I
10.1109/TPEL.2010.2052472
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel fast-diagnostic method for open-switch faults in inverters without sensors is proposed to improve the reliability of power electronic system in this paper. The presented method is achieved by analysis of switching function model of the inverter under both healthy and faulty conditions. Due to the different voltages endured by each power switch under healthy condition from open-switch faults in some cases, open-circuit faults can be detected by sensing the collector-emitter voltages of the lower power switches in each leg. The diagnostic scheme employs the simple hardware circuit to obtain indirectly the voltages of lower power switches and to get rid of high cost and complexity as a result of sensors. Also, this method minimizes the detection time and is available for the inverter faults in the systems with open-loop or closed-loop current control strategies. To ensure the effectiveness and reliability of the proposed diagnostic method, the rising-edge delays for switching signals are used to avoid misdiagnostic results because of the ON-OFF processes of power switches, and the delay durations are determined considering various factors. Simulation and experimental results validate the proposed scheme for detecting switch and leg open-circuit faults.
引用
收藏
页码:119 / 126
页数:8
相关论文
共 29 条
[1]   Adaptive neural fuzzy inference system for the detection of inter-turn insulation and bearing wear faults in induction motor [J].
Ballal, Makarand S. ;
Khan, Zafar J. ;
Suryawanshi, Hiralal M. ;
Sonolikar, Ram L. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (01) :250-258
[2]   Fault-Tolerant Reconfiguration System for Asymmetric Multilevel Converters Using Bidirectional Power Switches [J].
Barriuso, Pablo ;
Dixon, Juan ;
Flores, Patricio ;
Moran, Luis .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (04) :1300-1306
[3]   Innovative remedial strategies for inverter faults in IPM synchronous motor drives [J].
Bianchi, N ;
Bolognani, S ;
Zigliotto, M ;
Zordan, M .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2003, 18 (02) :306-314
[4]   Single current sensor technique in the DC link of three-phase PWM-VS inverters: A review and a novel solution [J].
Blaabjerg, F ;
Pedersen, JK ;
Jaeger, U ;
Thoegersen, P .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (05) :1241-1253
[5]   A multilevel converter topology with fault-tolerant ability [J].
Chen, A ;
Hu, L ;
Chen, LF ;
Deng, Y ;
He, XN .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (02) :405-415
[6]   Fault tolerant circuit topology and control method for input-series and output-parallel modular dc-dc converters [J].
Choudhary, Vijay ;
Ledezma, Enrique ;
Ayyanar, Raja ;
Button, Robert M. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (01) :402-411
[7]   Fault detection and diagnosis in an induction machine drive: A pattern recognition approach based on concordia stator mean current vector [J].
Diallo, D ;
Benbouzid, MEH ;
Hamad, D ;
Pierre, X .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (03) :512-519
[8]   A fault tolerant doubly fed induction generator wind turbine using a parallel grid side rectifier and series grid side converter [J].
Flannery, Patrick S. ;
Venkataramanan, Giri .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (03) :1126-1135
[9]  
Fuchs FW, 2003, IEEE IND ELEC, P1378
[10]   Fast power switch failure detection for fault tolerant voltage source inverters using FPGA [J].
Karimi, S. ;
Poure, P. ;
Saadate, S. .
IET POWER ELECTRONICS, 2009, 2 (04) :346-354