Prostate-specific antigen immunosensing based on mixed self-assembled monolayers, camel antibodies and colloidal gold enhanced sandwich assays

被引:167
作者
Huang, L
Reekmans, G
Saerens, D
Friedt, JM
Frederix, F
Francis, L
Muyldermans, S
Campitelli, A
Van Hoof, C
机构
[1] IMEC, MCP BIO, B-3001 Heverlee, Belgium
[2] Vrije Univ Brussels, Cellular & Mol Immunol Lab, Dept Mol & Cellular Interact, B-1050 Brussels, Belgium
[3] Univ Catholique Louvain, Unite Phys Chim & Phys Mat, B-1348 Louvain, Belgium
[4] MiniFAB Australia, Melbourne, Vic, Australia
关键词
PSA assay; camel antibody; self-assembled monotayer; SPR biosensor; gold nanoparticle enhancement;
D O I
10.1016/j.bios.2004.11.016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Prostate-specific antigen (PSA) is a valuable biomarker for prostate cancer screening. We developed a PSA immunoassay on a commercially available surface plasmon resonance biosensor. Our PSA receptor molecule consists of a single domain antigen-binding fragment, cAbPSA-N7, derived from dromedary heavy-chain antibodies and identified after phage display. It binds PSA with a high k(on) value of 1.9 x 10(6) M-1 s(-1), and was covalently immobilised on a gold substrate via a mixed self-assembled monolayer (SAM) of alkanethiols by using carbodiimide-coupling chemistry in 10 mM acetate buffer pH 5.5 to obtain an optimal pre-concentration. The best performing and optimised mixed SAM consisted of (10%) 16-mercapto-1-hexadecanoic acid (16-MHA) for covalent cAbPSA-N7 immobilisation and (90%) 11-mercapto-l-undecanol (11-MUOH) to minimise non-specific adsorption of the analyte. In this way, two advantages are incorporated in a single coupling layer. Up to 28 fmol/mm(2) of cAbPSA-N7 could be immobilised and 30% of its binding sites participate actively in PSA interaction. In addition, the optimised layer showed also optimal performance to assess physiological samples. Although PSA concentrations as low as 10 ng/ml could be detected directly, this detection limit could be enhanced to PSA levels in the sub ng/ml range by introducing a sandwich assay involving a biotinylated secondary antibody and streptavidin modified gold nanoparticles. This approach realises the PSA detection at clinical relevant concentrations. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:483 / 490
页数:8
相关论文
共 44 条
[21]   DEVELOPMENT OF A HIGHLY SENSITIVE IMMUNOCHEMILUMINOMETRIC ASSAY FOR PROSTATE-SPECIFIC ANTIGEN [J].
KLEE, GG ;
PREISSNER, CM ;
OESTERLING, JE .
UROLOGY, 1994, 44 (01) :76-82
[22]  
Krumholtz JS, 2002, UROLOGY, V60, P469, DOI 10.1016/S0090-4295(02)01875-7
[23]   Antibody arrays prepared by cutinase-mediated immobilization on self-assembled monolayers [J].
Kwon, Y ;
Han, ZZ ;
Karatan, E ;
Mrksich, M ;
Kay, BK .
ANALYTICAL CHEMISTRY, 2004, 76 (19) :5713-5720
[24]   Colloidal Au-enhanced surface plasmon resonance immunosensing [J].
Lyon, LA ;
Musick, MD ;
Natan, MJ .
ANALYTICAL CHEMISTRY, 1998, 70 (24) :5177-5183
[25]   Surface plasmon resonance of colloidal Au-modified gold films [J].
Lyon, LA ;
Musick, MD ;
Smith, PC ;
Reiss, BD ;
Peña, DJ ;
Natan, MJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) :118-124
[26]  
Malan A, 1998, THIN FILMS SELF ASSE
[27]   Ultraviolet-ozone jet cleaning process of organic surface contamination layers [J].
Moon, DW ;
Kurokawa, A ;
Ichimura, S ;
Lee, HW ;
Jeon, IC .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1999, 17 (01) :150-154
[28]  
Muyldermans S, 2001, J Biotechnol, V74, P277
[29]   Functional heavy-chain antibodies in Camelidae [J].
Nguyen, VK ;
Desmyter, A ;
Muyldermans, S .
ADVANCES IN IMMUNOLOGY, VOL 79, 2001, 79 :261-296
[30]   AN ANALYTICAL COMPARISON OF THE 3 MOST COMMONLY USED PROSTATE-SPECIFIC ANTIGEN ASSAYS - TANDEM-R, TANDEM-E, AND IMX [J].
OESTERLING, JE ;
MOYAD, MA ;
WRIGHT, GL ;
BECK, GR .
UROLOGY, 1995, 46 (04) :524-532