Detection and characterization of phospholipase D by flow injection analysis

被引:9
作者
Becker, M
Spohn, U
UlbrichHofmann, R
机构
[1] Martin-Luther-Univ. Halle/Wittenberg, Institut für Biotechnologie, D-06120 Halle
关键词
D O I
10.1006/abio.1996.9864
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A precisely working automated system for the investigation of phospholipases D (PLDs, EC 3.1.4.4) from plant and microbial sources with how injection analysis (FIA) has been developed. The two versions of the FIA setup described are based on the oxidation of choline liberated from phosphatidylcholine by PLD action and catalyzed by choline oxidase and the chemiluminescence detection of hydrogen peroxide produced by this reaction. The correlation between this chemiluminescence signal and the PLD activity was linear in the range between 1 and 100 mU/ml PLD. The sampling frequency was 12 samples per hour. This method was used to compare three different PLDs from cabbage and microbial sources with respect to their pH optima, temperature stability, effecters, and v/[S] characteristics. (C) 1997 Academic Press, Inc.
引用
收藏
页码:55 / 61
页数:7
相关论文
共 56 条
[11]  
EBERHARDT R, 1996, THESIS RHEINISCH WES
[12]  
Eibl H., 1984, ANGEW CHEM-GER EDIT, V96, P247
[13]   TENSAMMETRIC DETERMINATION OF PHOSPHOLIPIDS IN BATCH AND FLOW-INJECTION SYSTEMS [J].
EMONS, H ;
SCHMIDT, T ;
STULIK, K .
ANALYST, 1989, 114 (12) :1593-1596
[14]  
EXTON JH, 1990, J BIOL CHEM, V265, P1
[15]   ENZYMATIC-HYDROLYSIS OF SHORT-CHAIN LECITHIN LONG-CHAIN PHOSPHOLIPID UNILAMELLAR VESICLES - SENSITIVITY OF PHOSPHOLIPASES TO MATRIX PHASE STATE [J].
GABRIEL, NE ;
AGMAN, NV ;
ROBERTS, MF .
BIOCHEMISTRY, 1987, 26 (23) :7409-7418
[16]   AMPEROMETRIC SENSORS FOR PEROXIDE, CHOLINE, AND ACETYLCHOLINE BASED ON ELECTRON-TRANSFER BETWEEN HORSERADISH-PEROXIDASE AND A REDOX POLYMER [J].
GARGUILO, MG ;
HUYNH, N ;
PROCTOR, A ;
MICHAEL, AC .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :523-528
[17]   HYDROLYTIC ACTION OF PHOSPHOLIPASE-A2 IN MONOLAYERS IN THE PHASE-TRANSITION REGION - DIRECT OBSERVATION OF ENZYME DOMAIN FORMATION USING FLUORESCENCE MICROSCOPY [J].
GRAINGER, DW ;
REICHERT, A ;
RINGSDORF, H ;
SALESSE, C .
BIOCHIMICA ET BIOPHYSICA ACTA, 1990, 1023 (03) :365-379
[18]   DETERMINATION OF PLATELET-ACTIVATING-FACTOR BY A CHEMILUMINESCENCE METHOD AND ITS APPLICATION TO STIMULATED GUINEA-PIG NEUTROPHILS [J].
HASEGAWA, Y ;
KUNOW, E ;
SHINDOU, J ;
YUKI, H .
LIPIDS, 1991, 26 (12) :1117-1121
[19]  
Heller M, 1978, Adv Exp Med Biol, V101, P213
[20]   FLUORESCENCE-BASED ASSAYS OF LIPASES, PHOSPHOLIPASES, AND OTHER LIPOLYTIC ENZYMES [J].
HENDRICKSON, HS .
ANALYTICAL BIOCHEMISTRY, 1994, 219 (01) :1-8