Computed tomography perfusion of the liver: Assessment of pure portal blood flow studied with CT perfusion during superior mesenteric arterial portography

被引:13
作者
Kojima, H [1 ]
Tanigawa, N [1 ]
Komemushi, A [1 ]
Kariya, S [1 ]
Sawada, S [1 ]
机构
[1] Kansai Med Univ, Dept Radiol, Moriguchi, Osaka 5708507, Japan
关键词
computed tomography; liver; perfusion; portal vein; tomography; X-ray;
D O I
10.1080/02841850410001385
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantitatively assess the portal component of hepatic blood flow using computed tomography (CT) perfusion studies during superior mesenteric arterial portography. Material and Methods: Thirty-four patients with hepatocellular carcinoma and liver cirrhosis (LC) and 13 patients with liver metastasis without chronic liver disease were enrolled in this study. Ten milliliters of a non-ionic contrast medium (150 mgI) was injected at a rate of 5 rolls via a catheter placed in the superior mesenteric artery. Single-slice cine CT images at the level of the main trunk or the right/left main trunk of the portal vein were acquired over 40 s. The deconvolution method was then used on these CT images to measure blood flow (BF), blood volume (BV), and mean transit time (MTT) in (a) liver parenchyma in patients with HCC and liver cirrhosis; (b) liver parenchyma in patients with liver metastasis without cirrhosis; (c) directly in the HCC; and (d) directly in one of the metastases. Results: In 34 LC patients (a), BF, BV, and MTT in the liver parenchyma were 44.7 +/- 24.5 ml/min/ 100 g, 3.9 +/- 2.4 ml/100 g, and 10.9 +/- 5.5s, respectively. In 13 patients without cirrhosis (b), BF, BV, and MTT in the liver parenchyma were 89.6 +/- 52.0 ml/min/100g, 6.3 +/- 3.2 ml/100 g, and 8.7 +/- 3.6 sec, respectively. A significant difference in BF and BV was seen in patients with liver cirrhosis compared to those without cirrhosis. BF, BV, and MTT measured directly in HCC (c) were 6.5 +/- 4.5 ml/min/100g, 0.4 +/- 0.4 ml/100g, and 3.0 +/- 3.1 sec respectively, and BF, BV, and MTT in liver metastases (d) were 19.3 +/- 21.7 ml/min/100g, 0.6+0.8ml/100g, and 1.8 +/- 1.6 s, respectively. Conclusion: CT perfusion studies during superior mesenteric arterial portography allow quantitative assessment of pure portal blood flow in the liver.
引用
收藏
页码:709 / 715
页数:7
相关论文
共 28 条
[11]   Perfusion CT of the brain: Diagnostic approach for early detection of ischemic stroke [J].
Koenig, M ;
Klotz, E ;
Luka, B ;
Venderink, DJ ;
Spittler, JF ;
Heuser, L .
RADIOLOGY, 1998, 209 (01) :85-93
[12]   Oil-particle interactions in aquatic environments: Influence on the transport, fate, effect and remediation of oil spills [J].
Lee, K .
SPILL SCIENCE & TECHNOLOGY BULLETIN, 2002, 8 (01) :3-8
[13]   Colorectal cancer: Diagnostic potential of CT measurements of hepatic perfusion and implications for contrast enhancement protocols [J].
Leggett, DAC ;
Kelley, BK ;
Bunce, IH ;
Miles, KA .
RADIOLOGY, 1997, 205 (03) :716-720
[14]   INFLUENCE OF THE DEGREE OF LIVER-FAILURE ON PORTAL BLOOD-FLOW IN PATIENTS WITH LIVER-CIRRHOSIS [J].
LJUBICIC, N ;
DUVNJAK, M ;
ROTKVIC, I ;
KOPJAR, B .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1990, 25 (04) :395-400
[15]   Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model [J].
Materne, R ;
Van Beers, BE ;
Smith, AM ;
Leconte, I ;
Jamart, J ;
Dehoux, JP ;
Keyeux, A ;
Horsmans, Y .
CLINICAL SCIENCE, 2000, 99 (06) :517-525
[16]   HEPATIC BLOOD-FLOW MEASUREMENT WITH INERT-GAS CLEARANCE [J].
MATHIE, RT .
JOURNAL OF SURGICAL RESEARCH, 1986, 41 (01) :92-110
[17]   FUNCTIONAL IMAGES OF HEPATIC PERFUSION OBTAINED WITH DYNAMIC CT [J].
MILES, KA ;
HAYBALL, MP ;
DIXON, AK .
RADIOLOGY, 1993, 188 (02) :405-411
[18]   Perfusion CT: a worthwhile enhancement? [J].
Miles, KA ;
Griffiths, MR .
BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (904) :220-231
[19]   CT derived Patlak images of the human kidney [J].
Miles, KA ;
Leggett, DAC ;
Bennett, GAJ .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (854) :153-158
[20]   COLOR PERFUSION IMAGING - A NEW APPLICATION OF COMPUTED-TOMOGRAPHY [J].
MILES, KA ;
HAYBALL, M ;
DIXON, AK .
LANCET, 1991, 337 (8742) :643-645