Various issues relating to computational fluid dynamics simulations of carotid bifurcation flow based on models reconstructed from three-dimensional ultrasound images

被引:24
作者
Augst, AD
Barratt, DC
Hughes, AD
Thom, SAM
Xu, XY
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Chem Engn & Chem Technol, London SW7 2AZ, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Clin Pharmacol & Therapeut, London, England
关键词
three-dimensional ultrasound; computational fluid dynamics; carotid artery; image processing; haemodynamics;
D O I
10.1243/095441103770802568
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computational fluid dynamics (CFD) flow simulation techniques have the potential to enhance understanding of how haemodynamic factors are involved in atherosclerosis. Recently, three-dimensional ultrasound has emerged as an alternative to other three-dimensional imaging techniques, such as magnetic resonance angiography (MRA). The method can be used to generate accurate vascular geometry suitable for CFD simulations and can be coupled with Doppler ultrasound to provide physiologically realistic flow boundary conditions. However, there are various ways to utilize the flow data acquired, possibly leading to different results regarding both flow and wall shear stress patterns. A disadvantage of three-dimensional ultrasound for imaging the carotid bifurcation has been established as being the scanning limitation of the jawbone position. This may make artificial extensions of the internal and/or external carotid arteries necessary, which in turn may influence the predicted flow patterns. Flow simulations were carried out for three outflow calculation schemes as well as four geometries with different extensions to the carotid daughter vessels. It was found that variation of flow patterns was more strongly influenced by the outflow conditions than by the extensions of the daughter vessels. Consequently, it is recommended that for future CFD simulations of carotid flow using three-dimensional ultrasound data, the outflow boundary conditions should rely on the most accurate measurement available, and flow data recorded in the common and internal carotid are considered more reliable than data from the external carotid. Even though the extended lengths of the daughter vessels have insignificant effects on the predicted haemodynamic parameters, it would be a safer option to extend the internal carotid by approximately three times the diameter of the common carotid artery.
引用
收藏
页码:393 / 403
页数:11
相关论文
共 17 条
[1]   Volumetric assessment of carotid artery bifurcation using freehand-acquired, compound 3D ultrasound [J].
Allott, CP ;
Barry, CD ;
Pickford, R ;
Waterton, JC .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (855) :289-292
[2]   Accuracy and reproducibility of CFD predicted wall shear stress using 3D ultrasound images [J].
Augst, AD ;
Barratt, DC ;
Hughes, AD ;
Glor, FP ;
Thom, SAM ;
Xu, XY .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (02) :218-222
[3]  
AUGST AD, 2001, P 5 INT S COMP METH
[4]   Optimisation and evaluation of an electromagnetic tracking device for high-accuracy three-dimensional ultrasound imaging of the carotid arteries [J].
Barratt, DC ;
Davies, AH ;
Hughes, AD ;
Thom, SA ;
Humphries, KN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (07) :957-968
[5]   Accuracy of an electromagnetic three-dimensional ultrasound system for carotid artery imaging [J].
Barratt, DC ;
Davies, AH ;
Hughes, AD ;
Thom, SA ;
Humphries, KN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (10) :1421-1425
[6]  
BARRATT DC, 2002, THESIS LONDON U
[7]   Simulation of particle-hemodynamics in a partially occluded artery segment with implications to the initiation of microemboli and secondary stenoses [J].
Buchanan, JR ;
Kleinstreuer, C .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (04) :446-454
[8]   Relation between non-uniform hemodynamics and sites of altered permeability and lesion growth at the rabbit aorto-celiac junction [J].
Buchanan, JR ;
Kleinstreuer, C ;
Truskey, GA ;
Lei, M .
ATHEROSCLEROSIS, 1999, 143 (01) :27-40
[9]   CT ANGIOGRAPHY - APPLICATION TO THE EVALUATION OF CAROTID-ARTERY STENOSIS [J].
DILLON, EH ;
VANLEEUWEN, MS ;
FERNANDEZ, MA ;
EIKELBOOM, BC ;
MALI, WPTM .
RADIOLOGY, 1993, 189 (01) :211-219
[10]  
GLAGOV S, 1988, ARCH PATHOL LAB MED, V112, P1018