Strut Coverage and Vessel Wall Response to a New-Generation Paclitaxel-Eluting Stent With an Ultrathin Biodegradable Abluminal Polymer Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI)

被引:56
作者
Guagliumi, Giulio [1 ]
Sirbu, Vasile [1 ]
Musumeci, Giuseppe [1 ]
Bezerra, Hiram G. [2 ]
Aprile, Alessandro [1 ]
Kyono, Hiroyuki [2 ]
Fiocca, Luigi [1 ]
Matiashvili, Aleksandre [1 ]
Lortkipanidze, Nikoloz [1 ]
Vassileva, Angelina [1 ]
Popma, Jeffrey J. [4 ]
Allocco, Dominic J. [3 ]
Dawkins, Keith D. [3 ]
Valsecchi, Orazio [1 ]
Costa, Marco A. [2 ]
机构
[1] Ospedali Riuniti Bergamo, Cardiovasc Dept, Div Cardiol, I-24128 Bergamo, Italy
[2] Case Western Reserve Univ, Sch Med, Univ Hosp Case Med Ctr, Cleveland, OH USA
[3] Boston Sci Corp, Natick, MA USA
[4] Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
关键词
optical coherence tomography; biodegradable polymer; drug-eluting stent; stent thrombosis; paclitaxel; DURABLE POLYMER; CORONARY-ARTERY; BARE-METAL; FOLLOW-UP; IMPLANTATION; THROMBOSIS; TRIAL; ULTRASOUND; DISEASE; LEADERS;
D O I
10.1161/CIRCINTERVENTIONS.110.950154
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Polymer-coated drug-eluting stents are effective in preventing restenosis but have been associated with delayed healing and incomplete strut coverage. It is unknown whether paclitaxel-eluting stents (PES) with minimal biodegradable abluminal coating enhances strut coverage while preventing neointimal hyperplasia. Using optical coherence tomography (OCT) as a primary imaging modality, we assessed the proportion of uncovered struts at 6-month follow-up in PES coated with durable versus ultrathin (<1 mu m) biodegradable abluminal polymers. Methods and Results-In this pilot trial, 60 patients with de novo lesions (<= 25 mm) in native coronary vessels were randomly assigned to receive either TAXUS Liberte PES or JACTAX PES, a Liberte stent with polymer deposited abluminally as microdots (JACTAX HD: 9.2 mu g each of polymer and paclitaxel per 16-mm stent; JACTAX LD: 5 mu g each). OCT follow-up occurred at 6 months with clinical follow-up through 1 year. The primary end point was percent uncovered struts by OCT. An independent core laboratory blinded to stent assignment analyzed images. The 6-month rate of uncovered struts per patient was 5.3 +/- 14.7% for TAXUS Liberte, 7.0 +/- 12.2% for JACTAX HD, and 4.6 +/- 7.3% for JACTAX LD (P=0.81); percent malapposed struts was 1.4 +/- 4.4%, 0.8 +/- 1.9%, and 1.1 +/- 2.8%, respectively (P=0.86). Strut-level intimal thickness was 0.20 +/- 0.10, 0.22 +/- 0.15, and 0.24 +/- 0.15 mm (P=0.64); percent volume obstruction by OCT was 22.2 +/- 12.8, 22.5 +/- 16.2, and 25.8 +/- 15.2 (P=0.69). There were no deaths, Q-wave myocardial infarctions, or stent thromboses through 1 year. Conclusions-JACTAX PES with an ultrathin microdot biodegradable abluminal polymer did not result in improved strut coverage at 6 months compared with TAXUS Liberte
引用
收藏
页码:367 / U154
页数:12
相关论文
共 28 条
[21]   Direct Stenting With the TAXUS Liberte Drug-Eluting Stent Results From the TAXUS ATLAS DIRECT STENT Study [J].
Ormiston, John A. ;
Mahmud, Ehtisham ;
Turco, Mark A. ;
Popma, Jeffrey J. ;
Weissman, Neil ;
Cannon, Louis A. ;
Mann, Tift ;
Lucca, Michael J. ;
Lim, Soo-Teik ;
Hall, Jack J. ;
McClean, Dougal ;
Dobies, David ;
Mandinov, Lazar ;
Baim, Donald S. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (02) :150-160
[22]   Local Determinants of Thrombus Formation Following Sirolimus-Eluting Stent Implantation Assessed by Optical Coherence Tomography [J].
Otake, Hiromasa ;
Shite, Junya ;
Ako, Junya ;
Shinke, Toshiro ;
Tanino, Yusuke ;
Ogasawara, Daisuke ;
Sawada, Takahiro ;
Miyoshi, Naolci ;
Kato, Hiroki ;
Koo, Bon-Kwon ;
Honda, Yasuhiro ;
Fitzgerald, Peter J. ;
Hirata, Ken-ichi .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) :459-466
[23]   The effect of variable dose and release kinetics on neointimal hyperplasia using a novel paclitaxel-eluting stent platform - The paclitaxel in-stent controlled elution study (PISCES) [J].
Serruys, PW ;
Sianos, G ;
Abizaid, A ;
Aoki, J ;
den Heijer, P ;
Bonnier, H ;
Smits, P ;
McClean, D ;
Verheye, S ;
Belardi, J ;
Condado, J ;
Pieper, M ;
Garnbone, L ;
Bressers, M ;
Symons, J ;
Sousa, E ;
Litvack, F .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (02) :253-260
[24]   Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents [J].
Stone, Gregg W. ;
Moses, Jeffrey W. ;
Ellis, Stephen G. ;
Schofer, Joachim ;
Dawkins, Keith D. ;
Morice, Marie-Claude ;
Colombo, Antonio ;
Schampaert, Erick ;
Grube, Eberhard ;
Kirtane, Ajay J. ;
Cutlip, Donald E. ;
Fahy, Martin ;
Pocock, Stuart J. ;
Mehran, Roxana ;
Leon, Martin B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (10) :998-1008
[25]   A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease [J].
Stone, GW ;
Ellis, SG ;
Cox, DA ;
Hermiller, J ;
O'Shaughnessy, C ;
Mann, JT ;
Turco, M ;
Caputo, R ;
Bergin, P ;
Greenberg, J ;
Popma, JJ ;
Russell, ME .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (03) :221-231
[26]   In Vivo Comparison Between Optical Coherence Tomography and Intravascular Ultrasound for Detecting Small Degrees of In-Stent Neointima After Stent Implantation [J].
Suzuki, Yoriyasu ;
Ikeno, Fumiaki ;
Koizumi, Tomomi ;
Tio, Fermin ;
Yeung, Alan C. ;
Yock, Paul G. ;
Fitzgerald, Peter J. ;
Fearon, William F. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (02) :168-173
[27]   A NEW APPROACH FOR THE QUANTIFICATION OF COMPLEX LESION MORPHOLOGY - THE GRADIENT FIELD TRANSFORM - BASIC PRINCIPLES AND VALIDATION RESULTS [J].
VANDERZWET, PMJ ;
REIBER, JHC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (01) :216-224
[28]   Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS):: a randomised non-inferiority trial [J].
Windecker, Stephan ;
Serruys, Patrick W. ;
Wandel, Simon ;
Buszman, Pawel ;
Trznadel, Stanislaw ;
Linke, Axel ;
Lenk, Karsten ;
Ischinger, Thomas ;
Klauss, Volker ;
Eberli, Franz ;
Corti, Roberto ;
Wijns, William ;
Morice, Marie Claude ;
di Mario, Carlo ;
Davies, Simon ;
van Geuns, Robert-Jan ;
Eerdmans, Pedro ;
van Es, Gerrit-Anne ;
Meier, Bernhard ;
Jueni, Peter .
LANCET, 2008, 372 (9644) :1163-1173