Trace metals in ambient air:: Hourly size-segregated mass concentrations determined by Synchrotron-XRF

被引:62
作者
Bukowiecki, N
Hill, M
Gehrig, R
Zwicky, CN
Lienemann, P
Hegedüs, F
Falkenberg, G
Weingartner, E
Baltensperger, U
机构
[1] Paul Scherrer Inst, Lab Atmospher Chem, CH-5232 Villigen, Switzerland
[2] Empa, Lab Air Pollut Environm Technol, CH-8600 Dubendorf, Switzerland
[3] DESY, Deutsch Elektronen Synchrotron, Hamburger Synchrotronstrahlungslabor, D-22603 Hamburg, Germany
关键词
D O I
10.1021/es048089m
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Trace metals are ubiquitous in urban ambient air, with mass concentrations in the range of a few mu g/m(3) down to less than 100 pg/m(3). To measure such low concentrations represents a challenge for chemical and physical analysis. In this study, ambient aerosol was collected in Zurich (Switzerland) in 1-h intervals and three size fractions (aerodynamic diameters 0.1-1 mu m, 1-2.5 mu m, and 2.5-10 mu m), using a three-stage rotating drum impactor (RDI). The samples were analyzed by energy-dispersive Synchrotron radiation X-ray fluorescence spectrometry (SR-XRF) to obtain size-segregated hourly elemental aerosol mass concentrations for Cr, Mn, Fe, Cu, Zn, Br, and Pb, along with S, Cl, and Ca under the selected experimental conditions. The high sensitivity of SR-XRF allowed for detection limits of < 50 pg/m(3) for most of the above elements, with a net analysis time of only 15 s per sample. The data obtained with this technique illustrate that there is a considerable gain of relevant information when time resolution for measurements is increased from 1 day to 1 h. The individual size fractions of a specific element may show significantly different short-term patterns.
引用
收藏
页码:5754 / 5762
页数:9
相关论文
共 18 条
[1]   The use of STIM and PESA to measure profiles of aerosol mass and hydrogen content, respectively, across mylar rotating drums impactor samples [J].
Bench, G ;
Grant, PG ;
Ueda, D ;
Cliff, SS ;
Perry, KD ;
Cahill, TA .
AEROSOL SCIENCE AND TECHNOLOGY, 2002, 36 (05) :642-651
[2]   Fine and ultrafine particles in the Zurich (Switzerland) area measured with a mobile laboratory:: an assessment of the seasonal and regional variation throughout a year [J].
Bukowiecki, N ;
Dommen, J ;
Prévôt, ASH ;
Weingartner, E ;
Baltensperger, U .
ATMOSPHERIC CHEMISTRY AND PHYSICS, 2003, 3 :1477-1494
[3]   Asian aerosol transport to Alaska during ACE-Asia [J].
Cahill, CF .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2003, 108 (D23)
[4]   COMPOSITION ANALYSES OF SIZE-RESOLVED AEROSOL SAMPLES TAKEN FROM AIRCRAFT DOWNWIND OF KUWAIT, SPRING 1991 [J].
CAHILL, TA ;
WILKINSON, K ;
SCHNELL, R .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1992, 97 (D13) :14513-14520
[5]   Hourly elemental composition and sources identification of fine and coarse PM10 particulate matter in four Italian towns [J].
D'Alessandro, A ;
Lucarelli, F ;
Mandò, PA ;
Marcazzan, G ;
Nava, S ;
Prati, P ;
Valli, G ;
Vecchi, R ;
Zucchiatti, A .
JOURNAL OF AEROSOL SCIENCE, 2003, 34 (02) :243-259
[6]  
GEHRIG R, 2002, P 11 INT S TRANSP AI, V81, P267
[7]   DETECTION OF TRANSMUTATIONAL ELEMENTS IN COPPER BY MEANS OF TOTAL-REFLECTION X-RAY-FLUORESCENCE SPECTROMETRY USING SYNCHROTRON-RADIATION [J].
HEGEDUS, F ;
WOBRAUSCHEK, P ;
STRELI, C ;
WINKLER, P ;
RIEDER, R ;
LADISICH, W ;
VICTORIA, M ;
RYON, RW ;
SOMMER, WF .
X-RAY SPECTROMETRY, 1995, 24 (05) :253-254
[8]  
Hinds W. C., 1999, AEROSOL TECHNOLOGY
[9]   Particle size distribution and particle mass measurements at urban, near-city and rural level in the Copenhagen area and Southern Sweden [J].
Ketzel, M ;
Wåhlin, P ;
Kristensson, A ;
Swietlicki, E ;
Berkowicz, R ;
Nielsen, OJ ;
Palmgren, F .
ATMOSPHERIC CHEMISTRY AND PHYSICS, 2004, 4 :281-292
[10]   A study of trace elements in atmospheric aerosols of the Eastern Siberia using neutron activation and synchrotron radiation X-ray fluorescence analysis [J].
Khodzher, TV ;
Obolkin, VA ;
Potemkin, VL ;
Bufelov, NS ;
Tomza, U ;
Rahn, KA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (1-2) :413-418