Absolute backscatter coefficient over a wide range of frequencies in a tissue-mimicking phantom containing two populations of scatterers

被引:54
作者
Roberjot, V
Bridal, SL
Laugier, P
Berger, G
机构
[1] Laboratoire d'Imagerie Paramétrique, URA CNRS 1458, Paris
关键词
D O I
10.1109/58.535501
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The acquisition and interpretation of in vivo ultrasonic measurements in tissue encounter problems associated with limited access to the region of interest, intermixed scattering structures with different characteristic dimensions, and system-dependent effects, This work addresses these problems by adapting and testing a technique for measuring the absolute attenuation and the absolute backscatter coefficient (effective backscatter cross section per unit volume of material), as a function of frequency, in a single-transducer backscatter configuration, The frequency-dependent attenuation and backscatter coefficients of a tissue-mimicking gelatin phantom containing a random distribution of two populations of scatterers were measured, Three transducers with different center frequencies and focusing characteristics were used in order to verify that system-dependent effects were removed by the technique and to investigate the change in the measured parameters across a broad range of frequencies (2 to 60 MHz), A spherical autocorrelation model was applied to measurements of the backscatter coefficient in order to estimate the size of scatterers. Measurements demonstrate that the backscatter and attenuation properties of a mixture of two distinct intermixed scatterer-size populations change as a function of the frequency range across which the model is applied, Comparison of both the magnitude and the frequency dependence of the experimental results with the theoretical prediction of the backscatter coefficient showed good agreement.
引用
收藏
页码:970 / 978
页数:9
相关论文
共 36 条
[21]   EVALUATION OF BACKSCATTERING COEFFICIENTS FOR EXCISED HUMAN-TISSUES - PRINCIPLES AND TECHNIQUES [J].
NICHOLAS, D ;
HILL, CR ;
NASSIRI, DK .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (01) :7-15
[22]   QUANTITATIVE BROAD-BAND ULTRASONIC BACKSCATTER - AN APPROACH TO NON-DESTRUCTIVE EVALUATION IN ACOUSTICALLY INHOMOGENEOUS MATERIALS [J].
ODONNELL, M ;
MILLER, JG .
JOURNAL OF APPLIED PHYSICS, 1981, 52 (02) :1056-1065
[23]  
ODONNELL M, 1981, J ACOUST SOC AM, V69, P580, DOI 10.1121/1.385433
[24]   DETECTION OF DIFFUSE LIVER-DISEASE BY QUANTITATIVE ECHOGRAPHY - DEPENDENCE ON A-PRIORI CHOICE OF PARAMETERS [J].
OOSTERVELD, BJ ;
THIJSSEN, JM ;
HARTMAN, PC ;
ROSENBUSCH, GJE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (01) :21-25
[25]   INVIVO ULTRASOUND BACKSCATTERING ESTIMATION FOR TUMOR-DIAGNOSIS - AN ANIMAL STUDY [J].
ROMIJN, RL ;
THIJSSEN, JM ;
VANDELFT, JL ;
DEWOLFFROUENDAAL, D ;
VANBEST, J ;
OOSTERHUIS, JA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (05) :471-479
[26]   ULTRASONIC DIFFERENTIATION OF INTRAOCULAR MELANOMAS - PARAMETERS AND ESTIMATION METHODS [J].
ROMIJN, RL ;
THIJSSEN, JM ;
OOSTERVELD, BJ ;
VERBEEK, AM .
ULTRASONIC IMAGING, 1991, 13 (01) :27-55
[27]   ANALYSIS AND MEASUREMENT OF ULTRASOUND BACKSCATTERING FROM AN ENSEMBLE OF SCATTERERS EXCITED BY SINE-WAVE BURSTS [J].
SIGELMANN, RA ;
REID, JM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1973, 53 (05) :1351-1355
[28]   CORRELATIONS BETWEEN ACOUSTIC AND TEXTURE PARAMETERS FROM RF AND B-MODE LIVER ECHOGRAMS [J].
THIJSSEN, JM ;
OOSTERVELD, BJ ;
HARTMAN, PC ;
ROSENBUSCH, GJE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (01) :13-20
[29]   CORRECTION [J].
UEDA, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1984, 75 (03) :1012-1012
[30]   SPECTRAL-ANALYSIS OF ECHOES FOR BACKSCATTERING COEFFICIENT MEASUREMENT [J].
UEDA, M ;
OZAWA, Y .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1985, 77 (01) :38-47