Direct electrochemistry of hemoglobin and its electrocatalytic effect based on its direct immobilization on carbon ionic liquid electrode

被引:136
作者
Safavi, Afsaneh [1 ]
Maleki, Norouz [1 ]
Moradlou, Omran [1 ]
Sorouri, Mohsen [1 ]
机构
[1] Shiraz Univ, Fac Sci, Dept Chem, Shiraz 71454, Iran
关键词
hemoglobin; carbon ionic liquid electrode; electrocatalysis; oxygen; hydrogen peroxide;
D O I
10.1016/j.elecom.2007.12.026
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Direct electrochemistry of hemoglobin (Hb) has been achieved by its direct immobilization on carbon ionic liquid electrode (CILE). CILE was immersed in a solution containing Hb and ionic liquid, octylpyridinium chloride ([OcPy][Cl]), to directly immobilize Hb on CILE. Cyclic voltammetry of modified electrode exhibited quasi-reversible peaks corresponding to Hb. The oxidation and reduction peak potentials of immobilized Hb in acetate buffer solution, pH 5.0 and at a scan rate of 0.1 V s(-1) were obtained at about -150 mV and -290 mV, respectively. The average surface coverage of the electroactive Hb adsorbed on the electrode surface was calculated as 8.4 x 10(-11) mol cm(-2). Hb retained its bioactivity on modified electrode and showed excellent electrocatalytic activity towards oxygen, hydrogen peroxide and nitrite. Hydrogen peroxide can be determined in the range of 1.0 x 10(-4)-5.0 x 10(-3) M. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:420 / 423
页数:4
相关论文
共 29 条
[1]   Ionic liquids in analytical chemistry [J].
Anderson, Jared L. ;
Armstrong, Daniel W. ;
Wei, Guor-Tzo .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :2892-2902
[2]  
Bard A., 1980, ELECTROCHEM METHODS
[3]   Electrochemical reduction of NO by myoglobin in surfactant film:: Characterization and reactivity of the nitroxyl (NO-) adduct [J].
Bayachou, M ;
Lin, R ;
Cho, W ;
Farmer, PJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (38) :9888-9893
[4]   Non-haloaluminate room-temperature ionic liquids in electrochemistry - A review [J].
Buzzeo, MC ;
Evans, RG ;
Compton, RG .
CHEMPHYSCHEM, 2004, 5 (08) :1106-1120
[5]   Direct electrochemical reduction of hemin in imidazolium-based ionic liquids [J].
Compton, DL ;
Laszlo, JA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 520 (1-2) :71-78
[6]   Phase transition and decomposition temperatures, heat capacities and viscosities of pyridinium ionic liquids [J].
Crosthwaite, JM ;
Muldoon, MJ ;
Dixon, JK ;
Anderson, JL ;
Brennecke, JF .
JOURNAL OF CHEMICAL THERMODYNAMICS, 2005, 37 (06) :559-568
[7]   Direct electron transfer and characterization of hemoglobin immobilized on a Au colloid-cysteamine-modified gold electrode [J].
Gu, HY ;
Yu, AM ;
Chen, HY .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 516 (1-2) :119-126
[8]   Amperometric biosensor based on direct electrochemistry of hemoglobin in poly-allylamine (PAA) film [J].
Kafi, A. K. M. ;
Lee, Dong-Yun ;
Park, Sang-Hyun ;
Kwon, Young-Soo .
THIN SOLID FILMS, 2007, 515 (12) :5179-5183
[9]   Development of a peroxide biosensor made of a thiolated-viologen and hemoglobin-modified gold electrode [J].
Kafi, A. K. M. ;
Lee, Dong-Yun ;
Park, Sang-Hyun ;
Kwon, Young-Soo .
MICROCHEMICAL JOURNAL, 2007, 85 (02) :308-313
[10]   ROTATING-RING-DISK ENZYME ELECTRODE FOR BIOCATALYSIS KINETIC-STUDIES AND CHARACTERIZATION OF THE IMMOBILIZED ENZYME LAYER [J].
KAMIN, RA ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1980, 52 (08) :1198-1205