Investigations into the use of a reverse scan in a quadrupole ion trap mass spectrometer

被引:17
作者
Dobson, G
Murrell, J
Despeyroux, D
Wind, F
Tabet, JC
机构
[1] Univ Paris 06, Lab Chim Struct Organ & Biol, CNRS UMR 7613, F-75005 Paris 05, France
[2] Dstl, Detect Dept, Salisbury SP4 0JQ, Wilts, England
[3] Ctr Etud Bouchet, F-91710 Vert Le Petit, France
关键词
D O I
10.1002/rcm.1101
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The forward scan (i.e. an increasing RF voltage ramp for the mass-selective instability scan) is commonly used as an analytical scan for ion detection with quadrupole ion trap instruments. A number of phenomena have been observed while using this scan technique. These include space charge effects resulting in the delayed ejection of ions from the ion trap, and the fragmentation of fragile ions producing very broad peaks. Here the use of a reverse scan (i.e. a decreasing RF voltage ramp) is examined to determine the effect of the above phenomena in this acquisition method. With regard to space charge effects, the apparent reduction of the carbon isotope spacing below one Thomson (for singly charged ions) that is observed with the forward scan is now replaced by an apparent increase in this spacing. The reverse scan, which optimizes at lower axial modulation ejection voltages than the forward scan, allows for the intact ejection of fragile ions under its typical operating conditions whereas the forward scan results in fragmentation. Reducing the axial modulation voltage for the ejection of ions in the forward scan results in less dissociation of the fragile ions during ion ejection, but with the observation of ghost peaks due to incomplete ejection of all of the ions at the resonance ejection condition. While performing the reverse scan experiment, the formation of product ions from dissociation of the MH+ ion has also been observed. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:1657 / 1664
页数:8
相关论文
共 29 条
[1]   EVALUATION OF THE DIPOLE-MOMENTS OF ORGANIC IONS IN THE GAS-PHASE [J].
BORTOLINI, O ;
OLIMPIERI, L ;
TRALDI, P .
ORGANIC MASS SPECTROMETRY, 1994, 29 (06) :273-276
[2]  
BORTOLINI O, 1995, PRACTICAL ASPECTS IO, V2, P145
[3]   MASS SHIFTS DUE TO ION-ION INTERACTIONS IN A QUADRUPOLE ION-TRAP MASS-SPECTROMETER [J].
CLEVEN, CD ;
COX, KA ;
COOKS, RG ;
BIER, ME .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (06) :451-454
[4]  
COOKS RG, 1991, RAPID COMMUN MASS SP, V5, P93
[5]   MASS SHIFTS AND LOCAL SPACE-CHARGE EFFECTS OBSERVED IN THE QUADRUPOLE ION-TRAP AT HIGHER RESOLUTION [J].
COX, KA ;
CLEVEN, CD ;
COOKS, RG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 144 (1-2) :47-65
[6]  
FJELDSTED J, 1988, P 36 ASMS C MASS SPE
[7]   Resolution of isobaric and isomeric ions using chemical shifts in an ion trap mass spectrometer [J].
Gill, LA ;
Wells, JM ;
Patterson, GE ;
Amy, JW ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 1998, 70 (20) :4448-4452
[8]   In situ optimization of the electrode geometry of the quadrupole ion trap [J].
Gill, LA ;
Amy, JW ;
Vaughn, WE ;
Cooks, RG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 188 (1-2) :87-93
[9]  
KELLY PE, 1982, Patent No. 4540884
[10]   SYSTEMATIC FACTORS AFFECTING HIGH MASS-RESOLUTION AND ACCURATE MASS ASSIGNMENT IN A QUADRUPOLE ION-TRAP [J].
LONDRY, FA ;
MARCH, RE .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 144 (1-2) :87-103