Implant survival and outcome after rotating-hinge total knee revision arthroplasty: a minimum 6-year follow-up

被引:43
作者
Gudnason, Asgeir [1 ]
Milbrink, Jan [1 ]
Hailer, Nils P. [1 ]
机构
[1] Univ Uppsala Hosp, Dept Orthopaed, Inst Surg Sci, S-75185 Uppsala, Sweden
关键词
Rotating hinge knee prostheses; Revision total knee arthroplasty; Aseptic loosening; REPLACEMENT; PROSTHESIS; DISLOCATION; EVOLUTION; CONDYLAR; SURGERY; SYSTEM; TERM;
D O I
10.1007/s00402-011-1330-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Data on long-time survival and clinical function of rotating hinge knee prostheses used in revision total knee arthroplasty (TKA) are scarce. We evaluate the outcome of 42 revision TKA in 38 patients using the Endo-model rotating hinge total knee prosthesis after a minimum of 6 years, with 10-year implant survival as our primary outcome measure. Only revision TKAs performed due to aseptic loosening were included, and the Swedish Knee Arthroplasty Register was consulted in order to ensure that patients unavailable for clinical follow-up had not been revised elsewhere. Mean follow-up was after 8.8 (6-18) years, mean age at revision surgery was 72 (55-88) years, and most patients had severe medical comorbidities (n = 31). At follow-up, four knees had been re-revised due to aseptic loosening, and five further knees underwent re-revision due to other reasons. With implant revision due to aseptic loosening as the endpoint, 10-year survival was 89.2%, and with implant revision due to any reason 10-year survival was 65.1%. 11 patients (13 knees) eligible for clinical follow-up were evaluated according to the Hospital for Special Surgery score (HSSS), the Knee Society scores (KSS), and by plain radiography. Mean HSSS was 67 (36-90), mean KSS-knee was 85 (73-96), and mean KSS-function was 29 (0-100). Radiography showed that no implant was in need of revision. Our results indicate that revision arthroplasty of the knee with this rotating hinge prosthesis can be performed with satisfactory or good results in an elderly population with severe comorbidities.
引用
收藏
页码:1601 / 1607
页数:7
相关论文
共 39 条
[1]
[Anonymous], 2008, SWEDISH KNEE ARTHROP
[2]
Common complications of total knee arthroplasty [J].
Ayers, DC ;
Dennis, DA ;
Johanson, NA ;
Pellegrini, VD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (02) :278-311
[3]
Long-Term Outcome of Total Knee Arthroplasty in Charcot Joint A 10-to 22-Year Follow-Up [J].
Bae, Dae Kyung ;
Song, Sang Jun ;
Yoon, Kyoung Ho ;
Noh, Jung Ho .
JOURNAL OF ARTHROPLASTY, 2009, 24 (08) :1152-1156
[4]
Barrack RL, 2001, CLIN ORTHOP RELAT R, P292
[5]
The use of a modular rotating hinge component in salvage revision total knee arthroplasty [J].
Barrack, RL ;
Lyons, TR ;
Ingraham, RQ ;
Johnson, JC .
JOURNAL OF ARTHROPLASTY, 2000, 15 (07) :858-866
[6]
Barrack RL, 2002, ORTHOPEDICS, V25, P1020
[7]
Competing events influence estimated survival probability - When is Kaplan-Meier analysis appropriate? [J].
Biau, David Jean ;
Latouche, Aurelien ;
Porcher, Raphael .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (462) :229-233
[8]
Rotating knee prosthesis - Surface or hinge replacement? [J].
Crova, M ;
Cenna, E ;
Olivero, C .
ORTHOPADE, 2000, 29 (Suppl 1) :S43-S44
[9]
Problems with the Rotaflex - A 10-year review of a rotating hinge prosthesis [J].
David, HG ;
Bishay, M ;
James, ETR .
JOURNAL OF ARTHROPLASTY, 1998, 13 (04) :402-408
[10]
GARVIN KL, 1995, CLIN ORTHOP RELAT R, P131