Results of indirect reduction and plating of femoral shaft nonunions after intramedullary nailing

被引:85
作者
Bellabarba, C
Ricci, WM
Bolhofner, BR
机构
[1] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98104 USA
[2] Washington Univ, Sch Med, Dept Orthopaed Surg, St Louis, MO USA
[3] Bayfront Med Ctr, Orthopaed Trauma Serv, St Petersburg, FL USA
关键词
diaphysis; femur; nonunion; plating;
D O I
10.1097/00005131-200105000-00004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To observe and report the clinical results of indirect plating techniques in the treatment of femoral shaft nonunions originally treated with intramedullary nailing. Design: prospective consecutive. Setting: Regional trauma center. Patients: A consecutive series of twenty-three patients with nonunion of femoral shaft fractures previously treated with intramedullary nailing. Intervention: Surgical treatment with indirect plating techniques using the AO 95-degree condylar blade plate in nonunions of the distal and proximal one thirds and broad large-fragment dynamic compression plating: in nonunions of the middle one third, with selective autologous cancellous bone grafting. Emphasis was placed on preoperative planning. intraoperative attention to soft tissue sparing and selection of the appropriately applied implant to correct deformity and obtain union. Main Outcome Measurements: Healing rate and time, operative blood loss and time, and incidence of complications, including hardware failure, loss of fixation, infection, and postoperative malalignment. Results: Twenty-one of the twenty-three nonunions healed without further. intervention Lit an average of twelve weeks (range 10 to 16 weeks) postoperatively. The two remaining patients (9 percent) had early breakage of their hardware, requiring repeat plating. Union in both of these cases occurred within sixteen weeks of the revision (12 and 16 weeks). Including the two patients requiring reoperation, all twenty-three nonunions healed at an average of seventeen weeks (range 10 to 24 weeks) from the initial plating procedure. There were no intraoperative complications. Average operative time was 164 minutes (range 120 to 240 minutes), and blood loss was 340 milliliters (range 200 to 700 milliliters). There were no cases of significant postoperative axial or rotational malalignment (more than 5 degrees), limb length discrepancy (more than I centimeter), or deep infections. Conclusions: Modern plating techniques an effective in the treatment of femoral shaft nonunions after intramedullary fracture fixation. The authors consider this method particularly valuable in the presence of deformity. Union occurred reliably with few complications.
引用
收藏
页码:254 / 263
页数:10
相关论文
共 60 条
[51]  
Weber B., 1976, PSEUDARTHROSIS
[52]  
WEBER BG, 1981, CLIN ORTHOP RELAT R, V161, P24
[53]   CLOSED INTRAMEDULLARY NAILING OF FEMORAL FRACTURES - A REPORT OF 520 CASES [J].
WINQUIST, RA ;
HANSEN, ST ;
CLAWSON, DK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (04) :529-539
[54]   INTERLOCKED NAILING FOR TREATMENT OF SEGMENTAL FRACTURES OF THE FEMUR [J].
WISS, DA ;
BRIEN, WW ;
STETSON, WB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (05) :724-728
[55]  
WISS DA, 1986, CLIN ORTHOP RELAT R, V212, P35
[56]   COMPARISON OF CORTICAL BONE ATROPHY SECONDARY TO FIXATION WITH PLATES WITH LARGE DIFFERENCES IN BENDING STIFFNESS [J].
WOO, SLY ;
AKESON, WH ;
COUTTS, RD ;
RUTHERFORD, L ;
DOTY, D ;
JEMMOTT, GF ;
AMIEL, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (02) :190-195
[58]  
WU CC, 1993, CAN J SURG, V36, P302
[59]   A SIMPLER SURGICAL TECHNIQUE TO TREAT ASEPTIC NONUNION-ASSOCIATED FEMORAL LENGTH DISCREPANCY [J].
WU, CC ;
SHIH, CH ;
LEE, ZL .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1992, 111 (03) :160-164
[60]   TREATMENT OF 84 CASES OF FEMORAL NONUNION [J].
WU, CC ;
SHIH, CH .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (01) :57-60