Geometrical optimization of a phased array coil for high-resolution MR imaging of the carotid arteries

被引:15
作者
Liffers, A
Quick, HH
Herborn, CU
Ermert, H
Ladd, ME
机构
[1] Ruhr Univ Bochum, High Frequency Engn Inst, D-44801 Bochum, Germany
[2] Univ Hosp, Dept Diagnost Radiol, Essen, Germany
关键词
high-resolution MRI; carotid arteries; phased array coils; SNR simulations;
D O I
10.1002/mrm.10526
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The geometry of an RF phased-array receiving coil for high-resolution MRI of the carotid artery, particularly the bifurcation, was optimized with respect to signal-to-noise ratio (SNR). A simulation tool was developed to determine homogeneity, sensitivity, and SNR for a given imaging situation. The algorithm takes into account the coil geometry, the parameters of the measured object, and the imaging parameters of the pulse sequence. The coil with the optimum geometry was implemented as a receive-only coil for 1.5 T and comparative SNR measurements with different coils were performed. The experimental SNR measurements verified the simulations. The optimized carotid artery phased array offered the best SNR over the desired field of view. In vivo high-resolution MRI of the carotid arteries of healthy volunteers and patients with known stenosis was conducted with the optimized phased array coil. The capability of the phased array coil for resolving components within the carotid artery walls is demonstrated. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:439 / 443
页数:5
相关论文
共 16 条
[1]  
[Anonymous], THEORIE ELEKTROMAGNE
[2]  
Chen CN, 1989, BIOMEDICAL MAGNETIC
[3]  
Elster A.D., 2001, Questions and answers in magnetic resonance imaging, V2nd
[4]   Clinical imaging of the high-risk or vulnerable atherosclerotic plaque [J].
Fayad, ZA ;
Fuster, V .
CIRCULATION RESEARCH, 2001, 89 (04) :305-316
[5]   A comparison of two methods for measuring the signal to noise ratio on MR images [J].
Firbank, MJ ;
Coulthard, A ;
Harrison, RM ;
Williams, ED .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12) :N261-N264
[6]  
Gabriel C., 1996, Environmental Health
[7]  
GLAGOV S, 1988, ARCH PATHOL LAB MED, V112, P1018
[8]   COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270
[9]   Surface coil phased arrays for high-resolution imaging of the carotid arteries [J].
Hayes, CE ;
Mathis, CM ;
Yuan, C .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01) :109-112
[10]  
LIFFERS A, 2000, P 8 SCI M ISMRM DENV, P1400