Experimental results of donor site filling for autologous osteochondral mosaicplasty

被引:66
作者
Feczkó, P
Hangody, L
Varga, J
Bartha, L
Diószegi, Z
Bodó, G
Kendik, Z
Módis, L
机构
[1] Uzsoki Hosp, Orthopaed & Trauma Dept, H-1145 Budapest, Hungary
[2] Uzsoki Hosp, Dept Urol, H-1145 Budapest, Hungary
[3] Semmelweis Univ, Orthopaed Clin, Budapest, Hungary
[4] Szent Istvan Univ, Fac Vet Sci, Budapest, Hungary
[5] Univ Debrecen, Sch Med, Dept Anat & Histol, H-4012 Debrecen, Hungary
关键词
mosaicplasty; hydroxilapatite; carbon; polyglyconate; collagen;
D O I
10.1016/S0749-8063(03)00402-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Autologous osteochondral mosaicplasty has become a treatment option for focal chondral and osteochondral defects in recent years. Excessive postoperative bleeding from the donor site was reported as a possible complication of the procedure. The purpose of this study was to investigate different biodegradable materials for donor site filling, which could prevent excessive postoperative bleeding from these sites but would allow reasonable blood clot formation on the articular surfaces of donor tunnels. Type of Study: Basic science evaluation. Methods: In an experimental model, "donor site plugs" made from hydroxylapatite, carbon fiber, polyglyconate-B, compressed collagen, and 2 versions of polycaprolactones were used to fill the bony tunnels created by harvesting. These materials were tested in 100 knees of 50 German Shepherd dogs to determine the quality of the repair tissue formation on the surfaces of the harvesting holes filled by these materials. Arthroscopies of the dogs were performed at several intervals, from 4 weeks to 26 weeks, and macroscopic studies were performed on euthanized animals between 8 weeks and 30 weeks to evaluate donor site filling and coverage. Empty donor tunnels served as controls for the evaluation of the different filling materials. Results: All tested materials effectively decreased postoperative bleeding. Hydroxylapatite, carbon rods, polyglyconate-B, and melted polycaprolactone materials showed a good integration to the surrounding cancellous bone, but these fillings showed only a limited repair tissue formation, even at 30 weeks postoperatively. Second-look arthroscopy and histologic evaluation of necropsies showed the best fibrocartilage coverage after filling by compressed collagen. Technical details of the filling also had certain importance in the quality of the repair tissue formation. Conclusions: According to histologic results, compressed collagen appears to be a good material to fill donor tunnels of osteochondral graft harvest. This material is substituted gradually by bone formation and its articular surface can serve as an appropriate scaffold for fibrocartilage coverage created by the natural intrinsic repair process.
引用
收藏
页码:755 / 761
页数:7
相关论文
共 23 条
[1]
Bodó G, 2000, ACTA VET HUNG, V48, P343, DOI 10.1556/AVet.48.2000.3.11
[2]
ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[3]
Browne J E, 2000, J Am Acad Orthop Surg, V8, P180
[4]
Ciccone W J 2nd, 2001, J Am Acad Orthop Surg, V9, P280
[5]
BIODEGRADABLE POLYMER SCAFFOLDS FOR TISSUE ENGINEERING [J].
FREED, LE ;
VUNJAKNOVAKOVIC, G ;
BIRON, RJ ;
EAGLES, DB ;
LESNOY, DC ;
BARLOW, SK ;
LANGER, R .
BIO-TECHNOLOGY, 1994, 12 (07) :689-693
[6]
HANGODY L, 2001, CLIN ORTHOP S, V391, P328
[7]
HANGODY L, 1997, OPERATIVE TECHNIQUES, V7, P312
[8]
HANGODY L, 2000, SURG KNEE, P357
[9]
Hangody L, 1997, ORTHOP INT, V5, P175
[10]
Jackson D W, 2001, J Am Acad Orthop Surg, V9, P37