A reliability study of the universal goniometer, fluid goniometer, and electrogoniometer for the measurement of ankle dorsiflexion

被引:54
作者
Rome, K [1 ]
Cowieson, F [1 ]
机构
[1] UNIV LONDON KINGS COLL, DIV BIOMED SCI, PHYSIOTHERAPY GRP, LONDON W8 7AH, ENGLAND
关键词
D O I
10.1177/107110079601700106
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study investigated the reliability of three goniometers, the universal, fluid, and electro-goniometers, in the measurement of ankle dorsiflexion. Intra- and interobserver reliability were assessed using 10 healthy volunteers and five observers. A standardized ankle position was used to measure full range of active dorsiflexion. Intraobserver reliability was assessed using one observer over two successive occasions. Interobserver reliability was assessed among five observers over five separate occasions. A one-factor analysis of variance to examine intraobserver reliability demonstrated no significant difference between each of the devices on the two occasions. A multifactorial analysis of variance demonstrated significant differences among observers and again among devices (P < 0.001). Secondary analysis for interdevice reliability demonstrated significant differences among the three devices (p < 0.1). The study suggests that each device cannot be used reliably among observers or be used interchangeably, and clinical judgment based on angular changes of less than 10 degrees are invalid if rigid protocols are not followed.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 24 条
[1]   ANKLE JOINT DORSIFLEXION - ESTABLISHMENT OF A NORMAL RANGE [J].
BAGGETT, BD ;
YOUNG, G .
JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 1993, 83 (05) :251-254
[2]   RELIABILITY OF HINDFOOT GONIOMETRY WHEN USING A FLEXIBLE ELECTROGONIOMETER [J].
BALL, P ;
JOHNSON, GR .
CLINICAL BIOMECHANICS, 1993, 8 (01) :13-19
[3]  
BEVANS JS, 1993, J BR PODIATR MED, V48, P137
[4]   NORMAL RANGE OF MOTION OF JOINTS IN MALE-SUBJECTS [J].
BOONE, DC ;
AZEN, SP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (05) :756-759
[5]   GONIOMETRIC RELIABILITY IN A CLINICAL SETTING - SUBTALAR AND ANKLE JOINT MEASUREMENTS [J].
ELVERU, RA ;
ROTHSTEIN, JM ;
LAMB, RL .
PHYSICAL THERAPY, 1988, 68 (05) :672-677
[6]   A BIOMECHANICAL ANALYSIS OF THE TALOCALCANEAL JOINT - INVITRO [J].
ENGSBERG, JR .
JOURNAL OF BIOMECHANICS, 1987, 20 (04) :429-442
[7]   CLINICAL MEASUREMENT OF RANGE OF MOTION - REVIEW OF GONIOMETRY EMPHASIZING RELIABILITY AND VALIDITY [J].
GAJDOSIK, RL ;
BOHANNON, RW .
PHYSICAL THERAPY, 1987, 67 (12) :1867-1872
[8]  
Goodwin J, 1992, Disabil Rehabil, V14, P10
[9]  
Low J L, 1976, Physiotherapy, V62, P227
[10]  
Nicolas A, 1989, CLIN REHABIL, P1, DOI DOI 10.1177/026921558900300101