Measuring noncalcified coronary atherosclerotic plaque using voxel analysis with MDCT angiography: A pilot clinical study

被引:16
作者
Clouse, Melvin E. [1 ,2 ]
Sabir, Adeel [1 ,2 ]
Yam, Chun-Shan [1 ,2 ]
Yoshimura, Norihiko [1 ,2 ]
Lin, Shezhang [1 ,2 ]
Welty, Francine [2 ,3 ]
Martinez-Clark, Pedro [2 ,3 ]
Raptopoulos, Vassilios [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA 02215 USA
[3] Beth Israel Deaconess Med Ctr, Dept Cardiol, Boston, MA 02215 USA
关键词
cardiac imaging; coronary artery wall; coronary imaging; CT angiography; MDCT; micro-CT; voxel analysis;
D O I
10.2214/AJR.07.2988
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to evaluate a new method using voxel analysis for quantifying noncalcified plaque in coronary arteries using MDCT angiography (MDCTA) compared with luminal stenosis by catheter coronary arteriography. MATERIALS AND METHODS. Forty-one normal and eight abnormal arterial cross sections with noncalcified plaque selected from 40 patients undergoing MDCTA were analyzed for percentage of stenosis and plaque volume using a voxel analysis technique. RESULTS. Using voxel analysis, the normal arterial wall thickness was determined to be 0.8 +/- 0.4 mm. Attenuation values (in Hounsfield units) for normal segments ranged between 30 and 175 H and for abnormal (plaque-containing) segments ranged from -49 to 139 H (p < 0.05). Plaque volume measurements varied from 0.90 to 156 mm(3) with good interobserver correlation (R-2 = 0.9671). Percentage of stenosis correlated with quantitative coronary arteriography measurement (R-2 = 0.55). Voxel analysis underestimated the percentage of stenosis (Pearson's correlation coefficient, 1.2; p = 0.03). CONCLUSION. The study shows that the voxel analysis technique appears to be an accurate and reproducible method to measure arterial wall thickness, noncalcified plaque, and degree of arterial stenosis using density values measured in Hounsfield units. The technique may be useful on further correlative studies.
引用
收藏
页码:1553 / 1560
页数:8
相关论文
共 39 条
[1]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[2]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT [J].
Becker, CR ;
Nikolaou, K ;
Muders, M ;
Babaryka, G ;
Crispin, A ;
Schoepf, UJ ;
Loehrs, U ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2003, 13 (09) :2094-2098
[5]   Evaluation of electron beam CT coronary angiography in healthy subjects [J].
Chernoff, DM ;
Ritchie, CJ ;
Higgins, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (01) :93-99
[6]  
Estes JM, 1998, J CARDIOVASC SURG, V39, P527
[7]  
Fayad ZA, 2000, CIRCULATION, V102, P506
[8]   INTRAVASCULAR ULTRASOUND IMAGING OF CORONARY-ARTERIES - IS 3 LAYERS THE NORM [J].
FITZGERALD, PJ ;
STGOAR, FG ;
CONNOLLY, AJ ;
PINTO, FJ ;
BILLINGHAM, ME ;
POPP, RL ;
YOCK, PG .
CIRCULATION, 1992, 86 (01) :154-158
[9]   New method of measuring coronary diameter by electron-beam computed tomographic angiography using adjusted thresholds determined by calibration with aortic opacity [J].
Funabashi, N ;
Kobayashi, Y ;
Kudo, M ;
Asano, M ;
Teramoto, K ;
Komuro, I ;
Rubin, GD .
CIRCULATION JOURNAL, 2004, 68 (08) :769-777
[10]   Coronary artery: Quantitative evaluation of normal diameter determined with electron-beam CT compared with cine coronary angiography - Initial experience [J].
Funabashi, N ;
Kobayashi, Y ;
Perlroth, M ;
Rubin, GD .
RADIOLOGY, 2003, 226 (01) :263-271