New method of measuring coronary diameter by electron-beam computed tomographic angiography using adjusted thresholds determined by calibration with aortic opacity

被引:13
作者
Funabashi, N
Kobayashi, Y
Kudo, M
Asano, M
Teramoto, K
Komuro, I
Rubin, GD
机构
[1] Chiba Univ, Grad Sch Med, Dept Cardiovasc Sci & Med, Chuo Ku, Chiba 2608670, Japan
[2] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
[3] GE Yokokawa Med Syst, Tokyo, Japan
[4] Osaka City Univ, Dept Internal Med 1, Osaka 558, Japan
关键词
adjusted thresholds; coronary artery; electron beam computed tomography; quantitative coronary angiography;
D O I
10.1253/circj.68.769
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In a previous study the adjusted thresholds at which the diameters of coronary arteries determined by enhanced electron-beam computed tomography (CT) scans are equal to the corresponding quantitative coronary angiography measurements were analyzed, and their correlation with maximum CT values for the vessel short axes was determined. A rapid accurate method for such measurements was sought by substituting maximum CT values for the descending aorta in the corresponding axial images for those for the short axes. Methods and Results In 8 patients, 179 sites were measured. Means (+/-SD) of adjusted thresholds and the maximum CT values for vessel short axes and the descending aorta in the corresponding axial images for all vessels were 108+/-66, 227+/-80, and 363+/-75 Hounsfield Unit (HU), respectively. Adjusted thresholds correlated with the maximum CT values for the corresponding vessel short axes and the descending aorta in the corresponding axial images, with R-2=0.55, 0.33, p<0.01, respectively. An abbreviated formula for use of maximum CT values for the descending aorta in the corresponding axial images was y=0.5x-75 (HU) (y = adjusted threshold, x = maximum CT value for the descending aorta in the corresponding axial image). Conclusions The abbreviated formula provided a rapid, accurate method for measurements independent of arterial enhancement.
引用
收藏
页码:769 / 777
页数:9
相关论文
共 18 条
[1]   Comparison of vessel diameters in electron beam tomography and quantitative coronary angiography [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Bachmann, K .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (01) :1-7
[2]   Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1964-1971
[3]   Intravenous three-dimensional coronary angiography using contrast enhanced electron beam computed tomography [J].
Budoff, MJ ;
Oudiz, RJ ;
Zalace, CP ;
Bakhsheshi, H ;
Goldberg, SL ;
French, WJ ;
Rami, TG ;
Brundage, BH .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (06) :840-845
[4]   Evaluation of electron beam CT coronary angiography in healthy subjects [J].
Chernoff, DM ;
Ritchie, CJ ;
Higgins, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (01) :93-99
[5]   Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography [J].
Fleischmann, D ;
Rubin, GD ;
Bankier, AA ;
Hittmair, K .
RADIOLOGY, 2000, 214 (02) :363-371
[6]  
Funabashi N, 1999, RADIOLOGY, V213P, P269
[7]   Usefulness of three-dimensional visualization of coronary arteries using electron-beam computed tomography data with volume rendering [J].
Funabashi, N ;
Matsumoto, A ;
Yoshida, T ;
Watanabe, S ;
Misumi, K ;
Masuda, Y .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2000, 64 (08) :644-646
[8]   Endoluminal perspective volume rendering of coronary arteries using electron-beam computed tomography [J].
Funabashi, N ;
Misumi, K ;
Ohnishi, H ;
Watanabe, M ;
Suzuki, Y ;
Imai, N ;
Yoshida, K ;
Komuro, I .
CIRCULATION JOURNAL, 2003, 67 (12) :1064-1067
[9]   Coronary artery: Quantitative evaluation of normal diameter determined with electron-beam CT compared with cine coronary angiography - Initial experience [J].
Funabashi, N ;
Kobayashi, Y ;
Perlroth, M ;
Rubin, GD .
RADIOLOGY, 2003, 226 (01) :263-271
[10]   Utility of three-dimensional volume rendering images using electron-beam computed tomography to evaluate possible causes of ischemia from an anomalous origin of the right coronary artery from the left sinus of Valsalva [J].
Funabashi, N ;
Kobayashi, Y ;
Rubin, GD .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2001, 65 (06) :575-578