Effect of enhanced external counterpulsation on dobutamine-induced left ventricular wall motion abnormalities in severe chronic angina pectoris

被引:12
作者
Bagger, JP
Hall, RJC
Koutroulis, G
Nihoyannopoulos, P
机构
[1] Hammersmith Hosp, Cardiothorac Directorate, London W12 0HS, England
[2] Univ London Imperial Coll Sci Technol & Med, NHLI, London, England
关键词
D O I
10.1016/j.amjcard.2003.10.045
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
We studied the effect of enhanced external counterpulsation (EECP) in 23 consecutive patients with stable angina pectoris who had a positive dobutamine stress echocardiogram. After EECP, stress-induced wall motion score (WMS) improved by greater than or equal to2 grades in 43% of the patients (n = 10); the average improvement was 5.3 +/- 3.8 compared with -0.6 +/- 3.0 in the remaining 13 patients (p = 0.007). The diastolic/ systolic augmentation ratio increased by 217% in response to the full course of EECP (p = 0.0002) among patients with improved WMS, and by 71% (p = 0.004) among the other patients; the increase was greater among patients with improved WMS than among patients with no improvement (p = 0.01). After EECP, Canadian Cardiovascular Society angina class improved from 3.1 +/- 0.6 to 2.2 +/- 0.7 (p <0.0001) in the entire group and exercise capacity increased by 73 seconds (p = 0.0002) in patients who were able to exercise (n = 18). (C) 2004 by Excerpta Medica, Inc.
引用
收藏
页码:465 / 467
页数:3
相关论文
共 11 条
[1]
*AM SOC ECH COMM S, 1989, J AM SOC ECHOCARDIOG, V2, P358
[2]
The multicenter study of enhanced external counterpulsation (MUST-EECP): Effect of EECP on exercise-induced myocardial ischemia and anginal episodes [J].
Arora, RR ;
Chou, TM ;
Jain, D ;
Fleishman, B ;
Crawford, L ;
McKiernan, T ;
Nesto, RW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (07) :1833-1840
[3]
Effects of Enhanced External Counterpulsation on Health-Related Quality of Life continue 12 months after treatment: A substudy of the Multicenter Study of Enhanced External Counterpulsation [J].
Arora, RR ;
Chou, TM ;
Jain, D ;
Fleishman, B ;
Crawford, L ;
McKiernan, T ;
Nesto, R ;
Ferrans, CE ;
Keller, S .
JOURNAL OF INVESTIGATIVE MEDICINE, 2002, 50 (01) :25-32
[4]
The international EECP patient registry (IEPR): Design, methods, baseline characteristics, and acute results [J].
Barsness, G ;
Feldman, AM ;
Holmes, DR ;
Holubkov, R ;
Kelsey, SF ;
Kennard, ED .
CLINICAL CARDIOLOGY, 2001, 24 (06) :435-442
[5]
Ikonomidis I, 1998, CORONARY ARTERY DIS, V9, P567
[6]
Relation of the pattern of diastolic augmentation during a course of enhanced external counterpulsation (EECP) to clinical benefit (from the international EECP patient registry [IEPR]) [J].
Lakshmi, MV ;
Kennard, ED ;
Kelsey, SF ;
Holubkov, R ;
Michaels, AD .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (11) :1303-+
[7]
Benefit and safety of enhanced external counterpulsation in treating coronary artery disease patients with a history of congestive heart failure [J].
Lawson, WE ;
Kennard, ED ;
Holubkov, R ;
Kelsey, SF ;
Strobeck, JE ;
Soran, O ;
Feldman, AM .
CARDIOLOGY, 2001, 96 (02) :78-84
[8]
ACCURACY OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY IN DETECTING CORONARY-ARTERY DISEASE [J].
MARCOVITZ, PA ;
ARMSTRONG, WF .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (16) :1269-1273
[9]
Does higher diastolic augmentation predict clinical benefit from enhanced external counterpulsation?: Data from the international EECP Patient Registry (IEPR) [J].
Michaels, AD ;
Kennard, ED ;
Kelsey, SF ;
Holubkov, R ;
Soran, O ;
Spence, S ;
Chou, TM .
CLINICAL CARDIOLOGY, 2001, 24 (06) :453-458
[10]
Two-dimensional stress echocardiography in coronary artery disease [J].
Nihoyannopoulos, P .
CURRENT OPINION IN CARDIOLOGY, 1996, 11 (04) :403-408