PCR biocompatibility of lab-on-a-chip and MEMS materials

被引:50
作者
Christensen, T. B.
Pedersen, C. M.
Groendhal, K. G.
Jensen, T. G.
Sekulovic, A.
Bang, D. D.
Wolff, A.
机构
[1] Tech Univ Denmark, Dept Micro & Nanotechnol, MIC, DK-2800 Lyngby, Denmark
[2] Danish Inst Food & Vet Res, Dept Poultry Fish & Fur Anim, DK-8200 Aarhus, Denmark
关键词
D O I
10.1088/0960-1317/17/8/015
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
DNA amplification using the polymerase chain reaction (PCR) is an important tool in biotechnology, pathogen surveillance in food, medical and forensic science etc. The PCR technique is now an important part of the research in and development of miniaturized biochemical analysis systems. However, reduced or no DNA amplification at all is an important challenge for microfabricated PCR devices due to a negative interaction between PCR chemicals and the surrounding environment, i.e. the materials encapsulating the PCR mix. Materials of special interest regarding PCR compatibility are silicon, glass and polymers, which are important in the fabrication of microelectromechanical systems (MEMS), micro total analysis systems (mu TAS) and lab-on-a-chip (LOC) systems. The PCR inhibition effect is a particularly important phenomenon in microsystems due to an increased surface-to-volume ratio which enhances the possibility of interaction between the surfaces and ingredients in the PCR mixture. By proper surface treatment the PCR reaction can be facilitated and in this paper we present a systematic and quantitative study of the impact on the PCR compatibility of a chemical and a biological surface treatment. The chemical treatments are based on the silanizing agent dichlordimethylsilane [(CH3)(2)SiCl2]], while the biological treatment is based on the protein bovine serum albumin (BSA). We present a simple model system for the investigation of the PCR compatibility of three widely used materials in microfabrication, namely silicon, glass and SU-8. The impact on PCR performance, measured by means of PCR efficiency, of untreated as well as chemically and biologically treated materials is studied. We show a convenient method of assessing the PCR compatibility of silicon, glass and SU-8 with a degree of information not presented before.
引用
收藏
页码:1527 / 1532
页数:6
相关论文
共 39 条
[1]   A miniature integrated device for automated multistep genetic assays [J].
Anderson, Rolfe C. ;
Su, Xing ;
Bogdan, Gregory J. ;
Fenton, Jeffery .
NUCLEIC ACIDS RESEARCH, 2000, 28 (12)
[2]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[3]   Chip PCR .2. Investigation of different PCR amplification systems in microfabricated silicon-glass chips [J].
Cheng, J ;
Shoffner, MA ;
Hvichia, GE ;
Kricka, LJ ;
Wilding, P .
NUCLEIC ACIDS RESEARCH, 1996, 24 (02) :380-385
[4]   Degenerate oligonucleotide primed polymerase chain reaction and capillary electrophoretic analysis of human DNA on microchip-based devices [J].
Cheng, J ;
Waters, LC ;
Fortina, P ;
Hvichia, G ;
Jacobson, SC ;
Ramsey, JM ;
Kricka, LJ ;
Wilding, P .
ANALYTICAL BIOCHEMISTRY, 1998, 257 (02) :101-106
[5]   Effects of single-walled carbon nanotubes on the polymerase chain reaction [J].
Cui, DX ;
Tian, FR ;
Kong, Y ;
Titushikin, I ;
Gao, HJ .
NANOTECHNOLOGY, 2004, 15 (01) :154-157
[6]   Silicon microchambers for DNA amplification [J].
Daniel, JH ;
Iqbal, S ;
Millington, RB ;
Moore, DF ;
Lowe, CR ;
Leslie, DL ;
Lee, MA ;
Pearce, MJ .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 71 (1-2) :81-88
[7]   Simulation and experimental validation of a SU-8 based PCR thermocycler chip with integrated heaters and temperature sensor [J].
El-Ali, J ;
Perch-Nielsen, IR ;
Poulsen, CR ;
Bang, DD ;
Telleman, P ;
Wolff, A .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 110 (1-3) :3-10
[8]   Development of a CMOS-compatible PCR chip:: comparison of design and system strategies [J].
Erill, I ;
Campoy, S ;
Rus, J ;
Fonseca, L ;
Ivorra, A ;
Navarro, Z ;
Plaza, JA ;
Aguiló, J ;
Barbé, J .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (11) :1558-1568
[9]   Biochemical analysis and optimization of inhibition and adsorption phenomena in glass-silicon PCR-chips [J].
Erill, I ;
Campoy, S ;
Erill, N ;
Barbé, J ;
Aguiló, J .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 96 (03) :685-692
[10]   Investigations on the compatibility of chemically oxidized silicon (SiOx)-surfaces for applications towards chip-based polymerase chain reaction [J].
Felbel, J ;
Bieber, I ;
Pipper, J ;
Köhler, JM .
CHEMICAL ENGINEERING JOURNAL, 2004, 101 (1-3) :333-338