A comparison of isokinetic strength testing and gait analysis in patients with posterior cruciate-retaining and substituting knee arthroplasties

被引:91
作者
Bolanos, AA [1 ]
Colizza, WA [1 ]
McCann, PD [1 ]
Gotlin, RS [1 ]
Wootten, ME [1 ]
Kahn, BA [1 ]
Insall, JN [1 ]
机构
[1] Beth Israel Med Ctr N, Insall Scott Kelly Inst Orthopaed & Sports Med, New York, NY 10128 USA
关键词
posterior cruciate-retaining prosthesis; posterior-stabilized prosthesis; gait analysis; isokinetic muscle testing; total knee arthroplasty;
D O I
10.1016/S0883-5403(98)90198-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fourteen patients with a posterior-stabilized prosthesis in one knee and a posterior cruciate-retaining prosthesis in the contralateral knee and both scoring good or excellent on the Hospital for Special Surgery (HSS) knee scale were evaluated by isokinetic muscle testing and comprehensive gait analysis at a mean follow-up of 98 months after arthroplasty. The average HSS knee score (93 points) and the average Knee Society score (94 points) were the same for the cruciate-retaining and posterior-stabilized knees. No differences were noted between the cruciate-retaining and the posterior stabilized knees with respect to isokinetic muscle testing parameters (peak torque, endurance, angle of peak torque, and torque acceleration energy) for both quadriceps and hamstrings. No significant differences were found between the cruciate-retaining and the posterior-stabilized knees with regard to gait parameters, knee range of motion, and electromyographic waveforms during level walking and stair climbing. Cruciate-retaining and posterior-stabilized total knee prostheses perform equally well during level gait and stair climbing.
引用
收藏
页码:906 / 915
页数:10
相关论文
共 57 条
[31]  
KROLL MA, 1989, CLIN ORTHOP RELAT R, V239, P191
[32]  
LAUGHMAN R K, 1984, Journal of Orthopaedic Research, V2, P307, DOI 10.1002/jor.1100020401
[33]   ISOMETRIC AND ISOKINETIC MEASUREMENT OF HAMSTRING AND QUADRICEPS STRENGTH [J].
LORD, JP ;
AITKENS, SG ;
MCCRORY, MA ;
BERNAUER, EM .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1992, 73 (04) :324-330
[34]  
MESSIER SP, 1992, ARCH PHYS MED REHAB, V73, P29
[35]  
MURRAY MP, 1983, CLIN ORTHOP RELAT R, P191
[36]  
OLSSON E, 1986, SCAND J REHABIL MED, V18, P101
[37]  
RAMAKRISHNAN HK, 1987, AM SOC MECH ENG BIOM
[38]  
RITTMAN N, 1981, CLIN ORTHOP RELAT R, P111
[39]   TOTAL CONDYLAR KNEE REPLACEMENT - A STUDY OF FACTORS INFLUENCING RANGE OF MOTION AS LATE AS 2 YEARS AFTER ARTHROPLASTY [J].
SCHURMAN, DJ ;
PARKER, JN ;
ORNSTEIN, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1006-1014
[40]  
SCUDERI GR, 1989, ORTHOP CLIN N AM, V20, P71