Immunosensor for the diagnosis of Chagas' disease

被引:29
作者
Ferreira, AAP
Colli, W
da Costa, PI
Yamanaka, H
机构
[1] UNESP, Inst Quim, BR-14800900 Araraquara, SP, Brazil
[2] Univ Sao Paulo, Inst Quim, BR-05508900 Sao Paulo, Brazil
[3] UNESP, Fac Ciencias Farmaceut, BR-14801902 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
T; cruzi; immunosensor; Chagas' disease;
D O I
10.1016/j.bios.2004.08.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Trypanosoma cruzi proteins from epimastigote membranes, herein referred as antigens, have been used for the construction of an amperometric immunosensor for serological diagnosis of Chagas' disease. The proteins used had a molecular mass ranging from 30 to 100 kDa. The gold electrode was treated with cysteamine and glutaraldehyde prior to antigen immobilization. Antibodies present in the serum of patients with Chagas' disease were captured by the immobilized antigens and the affinity interaction was monitored by chronoamperometry at a potential of -400 mV (versus Ag pseudo-reference electrode) using peroxidase-labeled IgG conjugate and hydrogen peroxide, iodide substrate. The incubation time to allow maximum antigen-antibody and antibody-peroxidase-labeled IgG interactions was 20 min with a reactivity threshold at -0.104 mu A. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 23 条
  • [1] BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
  • [2] TRANS-SIALIDASE - A UNIQUE ENZYME-ACTIVITY DISCOVERED IN THE PROTOZOAN TRYPANOSOMA-CRUZI
    COLLI, W
    [J]. FASEB JOURNAL, 1993, 7 (13) : 1257 - 1264
  • [3] The epidemiologic importance of Triatoma brasiliensis as a Chagas disease vector in Brazil:: a revision of domiciliary captures during 1993-1999
    Costa, J
    Almeida, CE
    Dotson, EM
    Lins, A
    Vinhaes, M
    Silveira, AC
    Ben Beard, C
    [J]. MEMORIAS DO INSTITUTO OSWALDO CRUZ, 2003, 98 (04): : 443 - 449
  • [4] Biosensors in clinical chemistry
    D'Orazio, P
    [J]. CLINICA CHIMICA ACTA, 2003, 334 (1-2) : 41 - 69
  • [5] Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125
    Dai, Z
    Yan, F
    Chen, J
    Ju, HX
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (20) : 5429 - 5434
  • [6] The impact of Chagas disease control in Latin America - A review
    Dias, JCP
    Silveira, AC
    Schofield, CJ
    [J]. MEMORIAS DO INSTITUTO OSWALDO CRUZ, 2002, 97 (05): : 603 - 612
  • [7] Spectral and kinetic studies on eosinophil peroxidase compounds I and II and their reaction with ascorbate and tyrosine
    Furtmüller, PG
    Jantschko, W
    Regelsberger, G
    Obinger, C
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-PROTEIN STRUCTURE AND MOLECULAR ENZYMOLOGY, 2001, 1548 (01): : 121 - 128
  • [8] Flow-through amperometric immunosensor: Fast 'sandwich' scheme immunoassay
    Ghindilis, AL
    Krishnan, R
    Atanasov, P
    Wilkins, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (05) : 415 - 423
  • [9] Improved direct piezoelectric biosensors operating in liquid solution for the competitive label-free immunoassay of 2,4-dichlorophenoxyacetic acid
    Horacek, J
    Skladal, P
    [J]. ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) : 43 - 50
  • [10] JENKINS SH, 1990, J CLIN IMMUNOASSAY, V13, P99