Hydrophilic coating aids radial sheath withdrawal and reduces patient discomfort following transradial coronary intervention: A randomized double-blind comparison of coated and uncoated sheaths

被引:54
作者
Kiemeneij, F [1 ]
Fraser, D [1 ]
Slagboom, T [1 ]
Laarman, GJ [1 ]
van der Wieken, R [1 ]
机构
[1] Onze Lieve Vrouw Hosp, Amsterdam Dept Intervent Cardiol, NL-1090 HM Amsterdam, Netherlands
关键词
transradial; coronary; angiography; intervention; introducer sheath; hydrophilic coating;
D O I
10.1002/ccd.10444
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Radial artery spasm may cause severe discomfort during radial artery sheath removal. A hydrophilic-coated sheath may reduce the force required to remove a radial sheath. This force may be quantified using an automatic pullback device (APD). The objective of this study was to assess if a hydrophilic coating reduces the required force and discomfort associated with removal of a radial sheath following transradial coronary intervention. Ninety patients undergoing percutaneous coronary intervention via the radial artery were randomly assigned to two groups receiving either coated or uncoated introducer sheaths. Radifocus Introducer II (Terumo) 25 cm, 6 Fr radial sheaths and sheaths that were identical apart from the presence of the coating were used in all patients. The APD was used for sheath removal at the end of the procedure. Three patients (7%) in the coated group experienced discomfort during automatic sheath removal, compared to 12 patients (27%) in the uncoated group (P = 0.02). The maximum pullback force (MPF) was significantly lower in the coated compared to the uncoated group (0.24 +/- 0.31 vs. 0.44 +/- 0.33 kg; P = 0.003). Similarly, the mean pullback force was significantly lower in the coated group (0.14 +/- 0.23 vs. 0.32 +/- 0.24 kg; P < 0.001). Only one patient (2%) in each group had an MPF greater than 1.0 kg together with clinical evidence of radial artery spasm. Removal of the coated Terumo Radifocus sheath requires less force than an identical uncoated sheath. The coated sheath was also associated with less discomfort for the patient. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:161 / 164
页数:4
相关论文
共 13 条
[1]   Reduction of discomfort at sheath removal during transradial coronary procedures with the use of a hydrophilic-coated sheath [J].
Dery, JP ;
Simard, S ;
Barbeau, GR .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (03) :289-294
[2]  
Goldberg SL, 1998, CATHETER CARDIO DIAG, V44, P147, DOI 10.1002/(SICI)1097-0304(199806)44:2<147::AID-CCD5>3.3.CO
[3]  
2-1
[4]   Characteristics of adrenoceptors in the human radial artery: Clinical implications [J].
He, GW ;
Yang, CQ .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (05) :1136-1141
[5]   COMPARISON AMONG ARTERIAL GRAFTS AND CORONARY-ARTERY - AN ATTEMPT AT FUNCTIONAL CLASSIFICATION [J].
HE, GW ;
YANG, CQ .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (04) :707-715
[6]   Coronary angiography from the radial artery - experience, complications and limitations [J].
Hildick-Smith, DJR ;
Lowe, MD ;
Walsh, JT ;
Ludman, PF ;
Stephens, NG ;
Schofield, PM ;
Stone, DL ;
Shapiro, LM ;
Petch, MC .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1998, 64 (03) :231-239
[7]   Evaluation of a spasmolytic cocktail to prevent radial artery spasm during coronary procedures [J].
Kiemeneij, F ;
Vajifdar, BU ;
Eccleshall, SC ;
Laarman, G ;
Slagboom, T ;
van der Wieken, R .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (03) :281-284
[8]   TRANSRADIAL ARTERY CORONARY ANGIOPLASTY [J].
KIEMENEIJ, F ;
LAARMAN, GJ ;
DEMELKER, E .
AMERICAN HEART JOURNAL, 1995, 129 (01) :1-7
[9]   Measurement of radial artery spasm using an automatic pullback device [J].
Kiemeneij, F ;
Vajifdar, BU ;
Eccleshall, SC ;
Laarman, G ;
Slagboom, T ;
van der Wieken, R .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (04) :437-441
[10]   Outpatient coronary stent implantation [J].
Kiemeneij, F ;
Laarman, GJ ;
Slagboom, T ;
vanderWieken, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) :323-327