Re-evaluating acridine orange for rapid flow cytometric enumeration of parasitemia in malaria-infected rodents

被引:29
作者
Bhakdi, Sebastian Chakrit
Sratongno, Panudda
Chimma, Pattamawan
Rungruang, Thanaporn
Chuncharunee, Aporn
Neumann, Hartmut R. H.
Malasit, Prida
Pattanapanyasat, Kovit [1 ]
机构
[1] Mahidol Univ, Siriraj Hosp, Fac Med, Off Res & Dev,Ctr Excellence Flow Cytometry,Div I, Bangkok 10700, Thailand
[2] Mahidol Univ, Siriraj Hosp, Fac Med, Off Res & Dev,Div Med Mol Biol, Bangkok 10700, Thailand
[3] Univ Freiburg, Dept Nephrol & Gen Med, Med Clin, Freiburg, Germany
[4] Inst Pasteur, Biomed Parasitol Unit, Dept Parasitol, Paris, France
[5] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Anat, Bangkok 10700, Thailand
关键词
acridine orange; flow cytometry; malaria; Plasmodium berghei; Plasmodium yoelii; reticulocytosis; rodents;
D O I
10.1002/cyto.a.20406
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Methods facilitating research in malaria are of pivotal relevance. Flow cytometry offers the possibility of rapid enumeration of parasitemia. It relies on staining the parasite DNA to distinguish between infected and non-infected red blood cell (RBC) populations. Unfortunately, in rodents abundant reticulocyte RNA interferes with the application of the method. This results in time-consuming sample preparation protocols that offer no clear advantage over microscopic counting. We reevaluated the use of the DNA/RNA discriminating vital fluorochrome acridine orange (AO) for rapid flow cytometric enumeration of parasitemia in rodents. Whole blood from rodents infected with Plasinodium berghei and Plasmodium yoelii was stained with AO and analyzed by flow cytometer. A newly developed two-channel (FL1/FL3) detection method was compared with conventional one-channel (FL1) detection and microscopic counting. The new AO two-channel detection method clearly discriminated between infected and non-infected RBC populations. It showed to be linear above parasiternias of 0.3%. Sample processing time amounted to approximately 5 min. It is shown that AO can be used for rapid, precise, and accurate enumeration of parasiternia in rodents. Due to its ease of handling the method might find widespread application in malaria research. (c) 2007 International Society for Analytical Cytology.
引用
收藏
页码:662 / 667
页数:6
相关论文
共 12 条
[1]   Optimisation of flow cytometric measurement of parasitaemia in plasmodium-infected mice [J].
Barkan, D ;
Ginsburg, H ;
Golenser, J .
INTERNATIONAL JOURNAL FOR PARASITOLOGY, 2000, 30 (05) :649-653
[2]   PLASMODIUM-FALCIPARUM - RAPID QUANTIFICATION OF PARASITEMIA IN FIXED MALARIA CULTURES BY FLOW-CYTOMETRY [J].
BIANCO, AE ;
BATTYE, FL ;
BROWN, GV .
EXPERIMENTAL PARASITOLOGY, 1986, 62 (02) :275-282
[3]   MICROSCOPIC AND FLOW CYTOPHOTOMETRIC ANALYSIS OF PARASITEMIA IN CULTURES OF PLASMODIUM-FALCIPARUM VITALLY STAINED WITH HOECHST-33342 - APPLICATION TO STUDIES OF ANTIMALARIAL AGENTS [J].
FRANKLIN, RM ;
BRUN, R ;
GRIEDER, A .
ZEITSCHRIFT FUR PARASITENKUNDE-PARASITOLOGY RESEARCH, 1986, 72 (02) :201-212
[4]   Mapping the global extent of malaria in 2005 [J].
Guerra, Carlos A. ;
Snow, Robert W. ;
Hay, Simon I. .
TRENDS IN PARASITOLOGY, 2006, 22 (08) :353-358
[5]   ANALYSIS OF PLASMODIUM-FALCIPARUM GROWTH IN CULTURE USING ACRIDINE-ORANGE AND FLOW-CYTOMETRY [J].
HARE, JD ;
BAHLER, DW .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1986, 34 (02) :215-220
[6]   CYTOFLUOROGRAPH DETECTION OF PLASMODIUM-YOELII, TRYPANOSOMA-GAMBIENSE, AND TRYPANOSOMA-EQUIPERDUM BY LASER-EXCITED FLUORESCENCE OF STAINED RODENT BLOOD [J].
JACKSON, PR ;
WINKLER, DG ;
KIMZEY, SL ;
FISHER, FM .
JOURNAL OF PARASITOLOGY, 1977, 63 (04) :593-598
[7]   PLASMODIUM SPECIES - FLOW-CYTOMETRY AND MICROFLUOROMETRY ASSESSMENTS OF DNA CONTENT AND SYNTHESIS [J].
JANSE, CJ ;
VANVIANEN, PH ;
TANKE, HJ ;
MONS, B ;
PONNUDURAI, T ;
OVERDULVE, JP .
EXPERIMENTAL PARASITOLOGY, 1987, 64 (01) :88-94
[8]   Improvement of detection specificity of Plasmodium-infected murine erythrocytes by flow cytometry using autofluorescence and YOYO-1 [J].
Jiménez-Díaz, MB ;
Rullas, J ;
Mulet, T ;
Fernández, L ;
Bravo, C ;
Gargallo-Viola, D ;
Angulo-Barturen, I .
CYTOMETRY PART A, 2005, 67A (01) :27-36
[9]   THIAZOLE ORANGE - A NEW DYE FOR PLASMODIUM SPECIES ANALYSIS [J].
MAKLER, MT ;
LEE, LG ;
RECKTENWALD, D .
CYTOMETRY, 1987, 8 (06) :568-570
[10]   FLOW CYTOMETRIC 2-COLOR STAINING TECHNIQUE FOR SIMULTANEOUS DETERMINATION OF HUMAN ERYTHROCYTE-MEMBRANE ANTIGEN AND INTRACELLULAR MALARIAL DNA [J].
PATTANAPANYASAT, K ;
WEBSTER, HK ;
UDOMSANGPETCH, R ;
WANACHIWANAWIN, W ;
YONGVANITCHIT, K .
CYTOMETRY, 1992, 13 (02) :182-187