Evaluation of the FIDIS vasculitis multiplex immunoassay for diagnosis and follow-up of ANCA-associated vasculitis and Goodpasture's disease

被引:30
作者
Damoiseaux, J.
Vaessen, M.
Knapen, Y.
Csernok, E.
Stegeman, C. A.
Van Paassen, P.
Tervaert, J. W. Cohen
机构
[1] Univ Hosp Maastricht, Dept Clin & Expt Immunol, NL-6229 HX Maastricht, Netherlands
[2] Univ Hosp Schleswig Holstein, Dept Rheumatol, Lubeck, Germany
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Nephrol, Groningen, Netherlands
来源
AUTOIMMUNITY, PART A: BASIC PRINCIPLES AND NEW DIAGNOSTIC TOOLS | 2007年 / 1109卷
关键词
ANCA; myeloperoxidase; proteinase; 3; glomerular basement membrane; multiplex immunoassay;
D O I
10.1196/annals.1398.051
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
We have evaluated a new-multiplex immunoassay (FIDIS Vasculitis) for simultaneous detection and quantification of anti-MPO, -PR3, and -glomerular basement membrane (GBM) antibodies in diagnosis and follow-up of ANCA-associated vasculitides (AAV) and Goodpasture's disease. ANCA were determined in sera of (a) 87 consecutive patients with biopsy-proven pauci-immune NCGN and 72 controls; (h) 9 patients with Goodpasture's disease; and (e) 60 WG patients and 60 controls, previously used in a multicenter comparison of direct and capture ELISA for PR3-ANCA. Finally, for prediction of relapses, PR3-ANCA was measured in samples preceding relapse in 23 PR3-AAV patients and in 23 matched PR3-AAV patients without relapse. The relative sensitivity of the FIDIS Vasculitis assay was 97.4% for MPO-ANCA and 92.3% for PR3-ANCA; specificity was 100% and 97.2%, respectively. Evaluation of the anti-GBM antibody detection revealed a sensitivity of 100% and a specificity of 99.6%. The sensitivity for WG of the PR3-ANCA detection (71.6%) approached the performance of capture ELISA (74%), although at the cost of specificity (96.7% versus 100%). For prediction of relapses a rise of 50% in ANCA level by FIDIS Vasculitis appeared optimal (ROC curve) for prediction of relapses. However, as compared to capture ELISA, both positive (63% versus 76%) and negative (68% versus 72%) predictive values were reduced. In conclusion, simultaneous detection of anti-MPO, -PR3, and -GBM antibodies in the multiplex FIDIS Vasculitis assay has excellent performance in terms of diagnosis of patients with AAV or Goodpasture's disease. However, detection of rises in PR3-ANCA for prediction of relapses gives less optimal results when compared to capture ELISA.
引用
收藏
页码:454 / 463
页数:10
相关论文
共 18 条
[1]   Autoantibody detection using multiplex technologies [J].
Binder, S. R. .
LUPUS, 2006, 15 (07) :412-421
[2]  
Boomsma MM, 2000, ARTHRITIS RHEUM-US, V43, P2025, DOI 10.1002/1529-0131(200009)43:9<2025::AID-ANR13>3.0.CO
[3]  
2-O
[4]   Image analysis: a novel approach for the quantification of antineutrophil cytoplasmic antibody levels in patients with Wegener's granulomatosis [J].
Boomsma, MM ;
Damoiseaux, JGMC ;
Stegeman, CA ;
Kallenberg, CGM ;
Patnaik, M ;
Peter, JB ;
Tervaert, JWC .
JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 274 (1-2) :27-35
[5]   Evaluation of capture ELISA for detection of antineutrophil cytoplasmic antibodies directed against proteinase 3 in Wegener's granulomatosis: first results from a multicentre study [J].
Csernok, E ;
Holle, J ;
Hellmich, B ;
Willem, J ;
Tervaert, C ;
Kallenberg, CGM ;
Limburg, PC ;
Niles, J ;
Pan, GL ;
Specks, U ;
Westman, K ;
Wieslander, J ;
De Groot, K ;
Gross, WL .
RHEUMATOLOGY, 2004, 43 (02) :174-180
[6]   Evaluation of a new fluorescent-enzyme immuno-assay for diagnosis and follow-up of ANCA-associated vasculitis [J].
Damoiseaux, JGMC ;
Slot, MC ;
Vaessen, M ;
Stegeman, CA ;
Van Paassen, P ;
Tervaert, JWC .
JOURNAL OF CLINICAL IMMUNOLOGY, 2005, 25 (03) :202-208
[7]   Variations in performance characteristics of commercial enzyme immunoassay kits for detection of antineutrophil cytoplasmic antibodies: what is the optimal cut off? [J].
Holle, JU ;
Hellmich, B ;
Backes, M ;
Gross, WL ;
Csernok, E .
ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 (12) :1773-1779
[8]   Small-vessel vasculitis [J].
Jennette, JC ;
Falk, RJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 337 (21) :1512-1523
[9]   Comparison of a multiplex, bead-based fluorescent assay and immunofluorescence methods for the detection of ANA and ANCA autoantibodies in human serum [J].
Nifli, Artemissia-Phoebe ;
Notas, George ;
Mamoulaki, Marilena ;
Niniraki, Maria ;
Ampartzaki, Vaso ;
Theodoropoulos, Panayiotis A. ;
Kopnitsky, Mark J. ;
Castanas, Elias .
JOURNAL OF IMMUNOLOGICAL METHODS, 2006, 311 (1-2) :189-197
[10]  
Rutgers A, 2003, Eur J Intern Med, V14, P287, DOI 10.1016/S0953-6205(03)00097-9