Measurement of lower-limb muscle spasticity: Intrarater reliability of Modified Modified Ashworth Scale

被引:104
作者
Ghotbi, Nastaran [1 ]
Ansari, Noureddin Nakhostin [1 ]
Naghdi, Soofia [1 ]
Hasson, Scott [2 ]
机构
[1] Univ Tehran Med Sci, Fac Rehabil, Tehran, Iran
[2] Angelo State Univ, Phys Therapy Dept, San Angelo, TX 76909 USA
关键词
ankle plantar flexors; hip adductors; intrarater; knee extensors; lower limb; MMAS; Modified Modified Ashworth Scale; muscle spasticity; rehabilitation; reliability; ELBOW FLEXOR SPASTICITY; INTERRATER RELIABILITY; MULTIPLE-SCLEROSIS; ADULT PATIENTS; TARDIEU SCALE; HEMIPLEGIA; STROKE;
D O I
10.1682/JRRD.2010.02.0020
中图分类号
R49 [康复医学];
学科分类号
100232 [康复医学];
摘要
The Modified Modified Ashworth Scale (MMAS) is a clinical instrument for measuring spasticity. Few studies have been performed on the reliability of the MMAS. The aim of the present study was to investigate the intrarater reliability of the MMAS for the assessment of spasticity in the lower limb. We conducted a test-retest study on spasticity in the hip adductors, knee extensors, and ankle plantar flexors. Each patient was measured by a hospital-based clinical physiotherapist. Twenty-three patients with stroke or multiple sclerosis (fourteen women, nine men) and a mean +/- standard deviation age of 37.3 +/- 14.1 years participated. The weighted kappa was moderate for the hip adductors (weighted kappa = 0.45, standard error [SE] = 0.16, p = 0.007), good for the knee extensors (weighted kappa = 0.62, SE = 0.12, p < 0.001), and very good for the ankle plantar flexors (weighted kappa = 0.85, SE = 0.05, p < 0.001). The kappa value for overall agreement was very good (weighted kappa = 0.87, SE = 0.03,p < 0.001). The reliability for the ankle plantar flexors was significantly higher than that for the hip adductors. The intrarater reliability of the MMAS in patients with lower-limb muscle spasticity was very good, and it can be used as a measure of spasticity over time.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 25 条
[1]
The relation between Ashworth scores and neuromechanical measurements of spasticity following stroke [J].
Alibiglou, Laila ;
Rymer, William Z. ;
Harvey, Richard L. ;
Mirbagheri, Mehdi M. .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2008, 5 (1)
[2]
Ansari NN, 2008, NEUROREHABILITATION, V23, P231
[3]
Ansari Noureddin Nakhostin, 2006, Physiotherapy Theory and Practice, V22, P119, DOI 10.1080/09593980600724188
[4]
Assessing the reliability of the Modified Modified Ashworth Scale between two physiotherapists in adult patients with hemiplegia [J].
Ansari, Noureddin Nakhostin ;
Naghdi, Soofia ;
Hasson, Scott ;
Fakhari, Zahra ;
Mashayekhi, Masoud ;
Herasi, Mona .
NEUROREHABILITATION, 2009, 25 (04) :235-240
[5]
Inter-rater reliability of the Modified Modified Ashworth Scale as a clinical tool in measurements of post-stroke elbow flexor spasticity [J].
Ansari, Noureddin Nakhostin ;
Naghdi, Soofia ;
Hasson, Scott ;
Mousakhani, Atefeh ;
Nouriyan, Azam ;
Omidvar, Zeinab .
NEUROREHABILITATION, 2009, 24 (03) :225-229
[6]
The Modified Tardieu Scale for the measurement of elbow flexor spasticity in adult patients with hemiplegia [J].
Ansari, Noureddin Nakhostin ;
Naghdi, Soofia ;
Hasson, Scott ;
Azarsa, Mohammad Hasan ;
Azarnia, Somaye .
BRAIN INJURY, 2008, 22 (13-14) :1007-1012
[7]
Ansari Noureddin Nakhostin, 2008, Physiotherapy Theory and Practice, V24, P205, DOI 10.1080/09593980701523802
[8]
ASHWORTH B, 1964, PRACTITIONER, V192, P540
[9]
Reliability of measurements obtained with the Modified Ashworth Scale in the lower extremities of people with stroke [J].
Blackburn, M ;
van Vliet, P ;
Mockett, SP .
PHYSICAL THERAPY, 2002, 82 (01) :25-34
[10]
INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207