Quantification of left ventricular function and mass in cardiac Dual-Source CT (DSCT) exams: comparison of manual and semiautomatic segmentation algorithms

被引:30
作者
Bastarrika, Gorka [1 ]
Arraiza, Mara [1 ]
Pueyo, Jesus C. [1 ]
Herraiz, Maria J. [1 ]
Zudaire, Beatriz [1 ]
Villanueva, Alberto [1 ]
机构
[1] Univ Navarra, Clin Univ, Dept Radiol, Pamplona 31008, Spain
关键词
dual-source computed tomography (DSCT); left ventricle; heart function; cardiac mass; segmentation; time-effectiveness;
D O I
10.1007/s00330-007-0849-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The purpose of our study was to evaluate reliability of left ventricular (LV) function and mass quantification in cardiac DSCT exams comparing manual contour tracing and a region-growing-based semiautomatic segmentation analysis software. Thirty-three consecutive patients who underwent cardiac DSCT exams were included. Axial 1-mm slices were used for the semiautomated technique, and short-axis 8-mm slice thickness multiphase image reconstructions were the basis for manual contour tracing. Left ventricular volumes, ejection fraction and myocardial mass were assessed by both segmentation methods. Length of time needed for both techniques was also recorded. Left ventricular functional parameters derived from semiautomatic contour detection algorithm were not statistically different from manual tracing and showed an excellent correlation (p < 0.001). The semiautomatic contour detection algorithm overestimated LV mass (180.30 +/- 44.74 g) compared with manual contour tracing (156.07 +/- 46.29 g) (p < 0.001). This software allowed a significant reduction of the time needed for global LV assessment (mean 174.16 +/- 71.53 s, p < 0.001). Objective quantification of LV function using the evaluated region-growing-based semiautomatic segmentation analysis software is feasible, accurate, reliable and time-effective. However, further improvements are needed to equal results achieved by manual contour tracing, especially with regard to LV mass quantification.
引用
收藏
页码:939 / 946
页数:8
相关论文
共 50 条
[1]
Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]
Left ventricular function: Correlation of quantitative gated SPECT and MR imaging over a wide range of values [J].
Bavelaar-Croon, CDL ;
Kayser, HWM ;
van der Wall, EE ;
de Roos, A ;
Dibbets-Schneider, P ;
Pauwels, EKJ ;
Germano, G ;
Atsma, DE .
RADIOLOGY, 2000, 217 (02) :572-575
[3]
Becker C, 1999, ROFO-FORTSCHR RONTG, V170, P99
[4]
Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography - Comparison with cine magnetic resonance imaging [J].
Belge, Benedicte ;
Coche, Emmanuel ;
Pasquet, Agnes ;
Vanoverschelde, Jean-Louis J. ;
Gerber, Bernhard L. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1424-1433
[5]
Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance - Are they interchangeable? [J].
Bellenger, NG ;
Burgess, MI ;
Ray, SG ;
Lahiri, A ;
Coats, AJS ;
Cleland, JGF ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2000, 21 (16) :1387-1396
[6]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]
Blobel J, 2003, ROFO-FORTSCHR RONTG, V175, P1264
[8]
Time-effectiveness, observer-dependence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT [J].
Boehm, T ;
Alkadhi, H ;
Roffi, M ;
Willmann, JK ;
Desbiolles, LM ;
Marincek, B ;
Wildermuth, S .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04) :529-537
[9]
Boese JM, 2000, RADIOLOGE, V40, P123, DOI 10.1007/s001170050020
[10]
Left ventricular hypertrophy as a predictor of coronary heart disease mortality and the effect of hypertension [J].
Brown, DW ;
Giles, WH ;
Croft, JB .
AMERICAN HEART JOURNAL, 2000, 140 (06) :848-856