Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement

被引:66
作者
Pirker, W. [1 ]
Kocher, A. [1 ]
机构
[1] Med Univ Innsbruck, A-1090 Vienna, Austria
关键词
D O I
10.1016/j.ijom.2007.11.008
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
This report demonstrates the successful clinical use of a modified root-analogue zirconia implant for immediate single tooth replacement. A right maxillary premolar was removed and a custom-made, root-analogue, roughened zirconia implant with macro-retentions in the interdental space was fabricated and placed into the extraction socket 4 days later. Four months after root implantation a composite crown was cemented. No complications occurred during the healing period. An excellent esthetic and functional result was achieved with the composite crown. No clinically noticeable bone resorption or soft-tissue recession was observed at 26 months follow up. Significant modifications such as macro-retentions seem to indicate that primary stability and excellent osseointegration of immediate root-analogue zirconia implants can be achieved, while preventing unesthetic bone resorption. The macro-retentions must be limited to the interdental space to avoid fracture of the thin buccal cortex. This successful case warrants further clinical research in well controlled trials.
引用
收藏
页码:293 / 295
页数:3
相关论文
共 11 条
[1]
GUIDED TISSUE REGENERATION FOR IMPLANTS PLACED INTO EXTRACTION SOCKETS - A STUDY IN DOGS [J].
BECKER, W ;
BECKER, BE ;
HANDELSMAN, M ;
OCHSENBEIN, C ;
ALBREKTSSON, T .
JOURNAL OF PERIODONTOLOGY, 1991, 62 (11) :703-709
[2]
Carlsson L, 1988, Int J Oral Maxillofac Implants, V3, P21
[3]
DENTAL POLYMER IMPLANT CONCEPT [J].
HODOSH, M ;
POVAR, M ;
SHKLAR, G .
JOURNAL OF PROSTHETIC DENTISTRY, 1969, 22 (03) :371-&
[4]
IVANOFF CJ, 1996, CLIN ORAL IMPLAN RES, V8, P386
[5]
Custom-made root analogue titanium implants placed into extraction sockets - An experimental study in monkeys [J].
Kohal, RJ ;
Hurzeler, MB ;
Mota, LF ;
Klaus, G ;
Caffesse, RG ;
Strub, JR .
CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (05) :386-392
[6]
Kohal RJ, 2002, DEUT ZAHNAERZTL Z, V57, P495
[7]
Lundgren D, 1992, Clin Oral Implants Res, V3, P136, DOI 10.1034/j.1600-0501.1992.030306.x
[8]
Oliva J, 2007, INT J ORAL MAX IMPL, V22, P430
[9]
SOLLAZZO V, 2007, DENT MAT
[10]
Long-term evaluation of hollow screw and hollow cylinder dental implants: Clinical and radiographic results after 10 years [J].
Telleman, Gerdien ;
Meijer, Henny J. A. ;
Raghoebar, Gerry M. .
JOURNAL OF PERIODONTOLOGY, 2006, 77 (02) :203-210