Long-term evaluation of hollow screw and hollow cylinder dental implants: Clinical and radiographic results after 10 years

被引:33
作者
Telleman, Gerdien
Meijer, Henny J. A.
Raghoebar, Gerry M.
机构
[1] Univ Groningen, Med Ctr, Dept Oral Maxillofacial Surg & Maxillofacial Pros, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Med Ctr, Fac Med Sci, NL-9700 RB Groningen, Netherlands
[3] Univ Groningen, Fac Med Sci, Sch Dent, Dept Oral Funct & Prosthet Dent, NL-9700 RB Groningen, Netherlands
关键词
aftercare; dental implants; long-term study; mouth; edentulous; overdenture;
D O I
10.1902/jop.2006.040346
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Background: In 1988, an implant manufacturer offered a new dental implant system, with a wide choice of hollow cylinder (HC) and hollow screw (HS) implants. The purpose of this retrospective study of HS and HC implants was to evaluate clinical and radiographic parameters of peri-implant tissue and to analyze surgical and prosthetic aftercare. Methods: A total of 89 HS and 26 HC implants in 38 edentulous patients were available for complete evaluation. The patients were treated with overdentures stabilized by two or four implants. The follow-up period was 10 years. Results: The results of the clinical evaluation showed a mean sulcus probing depth of 3.3 +/- 1.3 mm (range = 2 to 10 mm). The mean radiographic bone loss was 2.2 +/- 2.1 mm (range = 0. 1 to 12.2 mm). One implant (HS) was removed during the osseointegration period. Three other implants (two HS and one HC) in three patients had to be removed after 10 years. The survival rate of the HS implant (96.6%) was comparable to the HC implant (96.1%). The success rate of the HS implant (93.3%) was slightly more favorable compared to the HC implant (88.5%). The HS and HC implants met the Albrektsson criteria of success. Conclusions: HS and HC implants provide a stable base for long-term support of a mandibular overdenture. Furthermore, it is important to monitor peri-implant bone level by taking annual radiographs and measuring probing depth, especially after prolonged service.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 40 条
[1]
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[2]
Mandibular overdentures supported by two Branemark, IMZ or ITI implants - A prospective comparative preliminary study: One-year results [J].
Batenburg, RHK ;
Meijer, HJA ;
Raghoebar, GM ;
Van Oort, RP ;
Boering, G .
CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (06) :374-383
[3]
Bone height measurements on panoramic radiographs - The effect of shape and position of edentulous mandibles [J].
Batenburg, RHK ;
Stellingsma, K ;
Raghoebar, GM ;
Vissink, A .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1997, 84 (04) :430-435
[4]
Behneke A, 2002, INT J ORAL MAX IMPL, V17, P799
[5]
Evaluation of postsurgical crestal bone levels adjacent to non-submerged dental implants [J].
Bragger, U ;
Hafeli, U ;
Huber, B ;
Hammerle, CHF ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (04) :218-224
[6]
Correlations between radiographic, clinical and mobility parameters after loading of oral implants with fixed partial dentures - A 2-year longitudinal study [J].
Bragger, U ;
HugelPisoni, C ;
Burgin, W ;
Buser, D ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) :230-239
[7]
Brocard D, 2000, INT J ORAL MAX IMPL, V15, P691
[8]
Tissue integration of non-submerged implants 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants [J].
Buser, D. ;
Weber, H-P ;
Lang, N. P. .
CLINICAL ORAL IMPLANTS RESEARCH, 1990, 1 (01) :33-40
[9]
Long-term evaluation of non-submerged ITI implants .1. 8-year life table analysis of a prospective multi-center study with 2359 implants [J].
Buser, D ;
MericskeStern, R ;
Bernard, JP ;
Behneke, A ;
Behneke, N ;
Hirt, HP ;
Belser, UC ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) :161-172
[10]
Buser D A, 1988, Int J Oral Maxillofac Implants, V3, P173