Continuous sample recirculation in an opened-loop multicommutated flow system

被引:14
作者
Lapa, RAS
Lima, JLFC
Reis, BF
Santos, JLM
机构
[1] Univ Porto, Fac Farm, Dept Quim Fis, CEQUP, P-4050 Porto, Portugal
[2] Univ Sao Paulo, Ctr Energia Nucl Agr, Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
opened loop; multicommutated flow system; sample recirculation; dilution; chloride determination;
D O I
10.1016/S0003-2670(98)00561-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A continuous circulating multicommutated flow system based on an opened-loop configuration is proposed. The sample is inserted into the flow system and continuously recirculated until a suitable dilution level is attained, which is permanently surveyed by including the detector in the circular reactor. A continuous removal of the highly dispersed front and trailing zones of the sample plug improves dilution efficiency. The chromogenic reagent used as carrier solution is permanently renewed, which contributes to a constant renewal of the reaction zone increasing the reaction rate by reducing its dependence on the dispersion at the sample/reagent interface. The developed methodology was tested in the determination of chloride in parenteral solutions by the formation of the iron (III) thiocyanate complex with expansion of the linear range of determination up to 10 000 mg l(-1). Results were reproducible (RSD <1.8%) and in agreement with those obtained by the conventional procedure. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:103 / 110
页数:8
相关论文
共 24 条
[1]   ENZYMATIC METHODS FOR THE DETERMINATION OF ETHANOL BASED ON LINEAR AND CYCLIC FLOW-INJECTION SYSTEMS [J].
ALMUAIBED, AM ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) :161-172
[2]   CONTINUOUS SOLVENT-EXTRACTION IN A CLOSED-LOOP SYSTEM [J].
ATALLAH, RH ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1987, 59 (24) :2909-2914
[3]   CONTINUOUS-FLOW ANALYSIS FOR URIC-ACID IN BIOLOGICAL-FLUIDS, WITH IMMOBILIZED URICASE IN A CLOSED-LOOP SYSTEM [J].
IOB, A ;
MOTTOLA, HA .
ANALYTICAL CHEMISTRY, 1980, 52 (14) :2332-2336
[4]   A multicommutated flow system with on-line compensation of the Schlieren effect applied to the spectrophotometric determination of pindolol [J].
Lapa, RAS ;
Lima, JLFC ;
Reis, BF ;
Santos, JLM ;
Zagatto, EAG .
ANALYTICA CHIMICA ACTA, 1998, 366 (1-3) :209-215
[5]   FIA TUBULAR POTENTIOMETRIC DETECTORS BASED ON HOMOGENEOUS CRYSTALLINE MEMBRANES - THEIR USE IN THE DETERMINATION OF CHLORIDE AND SULFIDE IONS IN WATER [J].
LIMA, JLFC ;
ROCHA, LSM .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 38 (02) :127-133
[6]  
NETO JAG, 1994, ANAL CHIM ACTA, V285, P293
[7]   MULTISITE DETECTION IN FLOW-ANALYSIS .2. MONOSEGMENTED SYSTEMS WITH RELOCATING DETECTORS FOR THE SPECTROPHOTOMETRIC DETERMINATION OF BORON IN PLANTS [J].
NOGUEIRA, ARA ;
BRIENZA, SMB ;
ZAGATTO, EAG ;
LIMA, JLFC ;
ARAUJO, AN .
ANALYTICA CHIMICA ACTA, 1993, 276 (01) :121-125
[8]   Flow analysis with accuracy assessment [J].
Oliveira, CC ;
Sartini, RP ;
Zagatto, EAG ;
Lima, JLFD .
ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) :31-36
[9]   ZONE-SAMPLING PROCESSES IN FLOW-INJECTION ANALYSIS [J].
REIS, BF ;
JACINTHO, AO ;
MORTATTI, J ;
KRUG, FJ ;
ZAGATTO, EAG ;
BERGAMIN, H ;
PESSENDA, LCR .
ANALYTICA CHIMICA ACTA, 1981, 123 (JAN) :221-228
[10]   MULTICOMMUTATION IN FLOW-ANALYSIS .1. BINARY SAMPLING - CONCEPTS, INSTRUMENTATION AND SPECTROPHOTOMETRIC DETERMINATION OF IRON IN PLANT DIGESTS [J].
REIS, BF ;
GINE, MF ;
ZAGATTO, EAG ;
LIMA, JLFC ;
LAPA, RA .
ANALYTICA CHIMICA ACTA, 1994, 293 (1-2) :129-138