Direct determination of phosphate in soil extracts by potentiometric flow injection using a cobalt wire electrode

被引:33
作者
Chen, ZL [1 ]
Grierson, P [1 ]
Adams, MA [1 ]
机构
[1] Univ Western Australia, Dept Bot, Nedlands, WA 6907, Australia
基金
澳大利亚研究理事会;
关键词
flow injection; cobalt wire electrode; phosphate; soil extracts;
D O I
10.1016/S0003-2670(98)00137-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A system is described for the direct potentiometric flow injection analysis of phosphates using a cobalt wire electrode. It is proposed that the electrode response to phosphate is a result of CO3(PO)(2) precipitate formation at the electrode surface. The electrode response to phosphate was found to be depend on the phthalate concentration, carrier pH, flow rate and injected volume. A linear response with a slope of -41+/-0.5 mV/decade was obtained in the concentration range of 1.0x10(-5) -5.0x10(-3) M with a detection limit of 1x10(-6) M, using a carrier solution containing 25 mM potassium hydrogen phthalate at pH 4.0. The proposed method was used for the determination of soil extracts with a fast analysis, low cost, high sensitivity and selectivity. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 28 条
[1]   FLOW-INJECTION DETERMINATION OF PHOSPHATE SPECIES IN DETERGENTS WITH A CALCIUM ION-SELECTIVE ELECTRODE [J].
ALEXANDER, PW ;
KOOPETNGARM, J .
ANALYTICA CHIMICA ACTA, 1987, 197 :353-359
[2]   INDIRECT POTENTIOMETRIC DETERMINATION OF METAL-IONS BY FLOW-INJECTION ANALYSIS WITH A COPPER ELECTRODE [J].
ALEXANDER, PW ;
TROJANOWICZ, M ;
HADDAD, PR .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1984, 17 (04) :309-320
[3]   DETERMINATION OF TOTAL PHOSPHORUS IN WATERS AND WASTEWATERS BY ONLINE MICROWAVE-INDUCED DIGESTION AND FLOW-INJECTION ANALYSIS [J].
BENSON, RL ;
MCKELVIE, ID ;
HART, BT ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1994, 291 (03) :233-242
[4]   POTENTIOMETRIC PHOSPHATE SELECTIVE ELECTRODE BASED ON A MULTIDENDATE TIN(IV) CARRIER [J].
CHANIOTAKIS, NA ;
JURKSCHAT, K ;
RUHLEMANN, A .
ANALYTICA CHIMICA ACTA, 1993, 282 (02) :345-352
[5]   Flow-injection potentiometric detection of phosphates using a metallic cobalt wire ion-selective electrode [J].
Chen, ZL ;
DeMarco, R ;
Alexander, PW .
ANALYTICAL COMMUNICATIONS, 1997, 34 (03) :93-95
[6]   Potentiometric detection of carboxylic acids by flow injection analysis using a tungsten oxide electrode [J].
Chen, ZL ;
Alexander, PW .
ANALYTICA CHIMICA ACTA, 1996, 332 (2-3) :187-192
[7]   DETERMINATION OF SULFATE, ORTHO-PHOSPHATE, AND TRIPHOSPHATE IONS BY FLOW-INJECTION ANALYSIS WITH THE LEAD ION-SELECTIVE ELECTRODE AS DETECTOR [J].
COETZEE, JF ;
GARDNER, CW .
ANALYTICAL CHEMISTRY, 1986, 58 (03) :608-611
[8]   A NOVEL ENZYME SENSOR FOR THE DETERMINATION OF INORGANIC-PHOSPHATE [J].
CONRATH, N ;
GRUNDIG, B ;
HUWEL, S ;
CAMMANN, K .
ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) :47-52
[9]   FLOW-INJECTION DETERMINATION OF PHOSPHATE WITH A CADMIUM ION-SELECTIVE ELECTRODE [J].
DAVEY, DE ;
MULCAHY, DE ;
OCONNELL, GR .
TALANTA, 1990, 37 (07) :683-687
[10]  
Dean J., 1995, Analytical Chemistry Handbook