Enhanced surface plasmon resonance immunosensing using a streptavidin-biotinylated protein complex

被引:27
作者
Pei, RJ
Yang, XR
Wang, EK [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, Electroanalyt Chem Lab, Changchun 130022, Jilin, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Appl Chem, Natl Analyt Res Ctr Electrochem & Spect, Changchun 130022, Jilin, Peoples R China
关键词
D O I
10.1039/b007432m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we present a novel strategy for improving the sensitivity of surface plasmon resonance immunosensing using a streptavidin-biotinylated protein complex. This amplification strategy is based on the construction of a molecular complex between streptavidin and biotin labeled protein. The complex can be formed in a cross-linking network of molecules so that the amplification of the response signal will be realized due to the big molecular size of the complex. The results show that the amplification strategy causes a dramatic improvement of the detection sensitivity. hIgG protein could be detected in the range of 0.005-10 mug ml(-1).
引用
收藏
页码:4 / 6
页数:3
相关论文
共 16 条
[1]   3-DIMENSIONAL STRUCTURE OF AN ANTIGEN-ANTIBODY COMPLEX AT 2.8-A RESOLUTION [J].
AMIT, AG ;
MARIUZZA, RA ;
PHILLIPS, SEV ;
POLJAK, RJ .
SCIENCE, 1986, 233 (4765) :747-753
[2]   A vesicle capture sensor chip for kinetic analysis of interactions with membrane-bound receptors [J].
Cooper, MA ;
Hansson, A ;
Löfås, S ;
Williams, DH .
ANALYTICAL BIOCHEMISTRY, 2000, 277 (02) :196-205
[3]   Development and validation of an immunoreceptor assay for Simulect based on surface plasmon resonance [J].
Deckert, F ;
Legay, F .
ANALYTICAL BIOCHEMISTRY, 1999, 274 (01) :81-89
[4]   Convergent solutions to binding at a protein-protein interface [J].
DeLano, WL ;
Ultsch, MH ;
de Vos, AM ;
Wells, JA .
SCIENCE, 2000, 287 (5456) :1279-1283
[5]   A method of combining biocytin tract-tracing with avidin-biotin-peroxidase complex immunocytochemistry for pre-embedding electron microscopic labeling in neonatal tissue [J].
Erisir, A ;
Aoki, C .
JOURNAL OF NEUROSCIENCE METHODS, 1998, 81 (1-2) :189-197
[6]   Interfacial properties of biotin conjugate-avidin complexes studied by acoustic wave sensor [J].
Ghafouri, S ;
Thompson, M .
LANGMUIR, 1999, 15 (02) :564-572
[7]   SURFACE-PLASMON RESONANCE IMMUNOSENSORS - SENSITIVITY CONSIDERATIONS [J].
KOOYMAN, RPH ;
KOLKMAN, H ;
VANGENT, J ;
GREVE, J .
ANALYTICA CHIMICA ACTA, 1988, 213 (1-2) :35-45
[8]   BIOANALYSIS WITH SURFACE-PLASMON RESONANCE [J].
LOFAS, S ;
MALMQVIST, M ;
RONNBERG, I ;
STENBERG, E ;
LIEDBERG, B ;
LUNDSTROM, I .
SENSORS AND ACTUATORS B-CHEMICAL, 1991, 5 (1-4) :79-84
[9]   Colloidal Au-enhanced surface plasmon resonance immunosensing [J].
Lyon, LA ;
Musick, MD ;
Natan, MJ .
ANALYTICAL CHEMISTRY, 1998, 70 (24) :5177-5183
[10]   ENHANCED SURFACE-PLASMON RESONANCE INHIBITION TEST (ESPRIT) USING LATEX-PARTICLES [J].
SEVERS, AH ;
SCHASFOORT, RBM .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) :365-370