被引:68
作者
Baikie, ID [1 ]
Smith, PJS [1 ]
Porterfield, DM [1 ]
Estrup, PJ [1 ]
机构
[1] Marine Biol Lab, Biocurrents Res Ctr, Woods Hole, MA 02543 USA
关键词
D O I
10.1063/1.1149678
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a novel multitip scanning Kelvin probe which can measure changes in biological surface potential Delta V-s to within 2 mV and, quasisimultaneously monitor displacement to 1 mm. The control and measurement subcomponents are PC based and incorporate a flexible user interface permitting software control of each individual tip, measurement, and scan parameters. We review the mode of operation and design features of the scanning bio-Kelvin probe including tip steering, signal processing, tip calibration, and novel tip tracking/dithering routines. This system uniquely offers both tip-to-sample spacing control (which is essential to avoid spurious changes in Delta V-s due to variations in mean spacing) and a dithering routine to maintain tip orientation to the biological specimen, irrespective of the latter's movement. These features permit long term (>.48 h) "active'' tracking of the displacement and biopotentials developed along and around a plant shoot in response to an environmental stimulus, e.g., differential illumination (phototropism) or changes in orientation (gravitropism). (C) 1999 American Institute of Physics. [S0034-6748(99)04703-6].
引用
收藏
页码:1842 / 1850
页数:9
相关论文
共 61 条
[1]  
[Anonymous], The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science: Vol, V46, No, P278, DOI [10.1080/14786449808621172, DOI 10.1080/14786449808621172]
[2]  
Baikie I. D., 1994, Proceedings of the Second International Symposium on Ultra-Clean Processing of Silicon Surfaces (UCPSS '94), P65
[3]   INTEGRATED AUTOMATIC MODULAR MEASURING SYSTEM [J].
BAIKIE, ID ;
VANDERWERF, KO ;
HANEKAMP, LJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (09) :2075-2078
[4]   NOISE AND THE KELVIN METHOD [J].
BAIKIE, ID ;
MACKENZIE, S ;
ESTRUP, PJZ ;
MEYER, JA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (05) :1326-1332
[5]   ANALYSIS OF STRAY CAPACITANCE IN THE KELVIN METHOD [J].
BAIKIE, ID ;
VENDERBOSCH, E ;
MEYER, JA ;
ESTRUP, PJZ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (03) :725-735
[6]  
BAIKIE ID, 1992, MATER RES SOC SYMP P, V259, P149, DOI 10.1557/PROC-259-149
[7]   Low cost PC based scanning Kelvin probe [J].
Baikie, ID ;
Estrup, PJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (11) :3902-3907
[8]  
BAIKIE ID, 1991, MATER RES SOC SYMP P, V204, P363
[9]   AUTOMATIC KELVIN PROBE COMPATIBLE WITH ULTRAHIGH-VACUUM [J].
BAIKIE, ID ;
VANDERWERF, KO ;
OERBEKKE, H ;
BROEZE, J ;
VANSILFHOUT, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (05) :930-934
[10]  
BAIKIE ID, 1993, MATER RES SOC S P, V315, P311